Important safeguards

1) Before use, please read this instruction carefully and use the power supply strictly according to

the instruction.

2) This power supply is for indoor use only and shall be installed in distribution box which can

provide the protection mechanism for avoid electric shock.

3) Please keep this equipment from humidity.

4) Before use, the input and output voltage must be checked to secure correct use.

5) The cover may under no circumstances be opened. If the cover is damaged, then the adaptor

may no longer be used.

6) The power supply shall be installed and used according to national wiring rules.

7) For indoor use only.

8) The product is not a toy, keep it where the children can not reach it.

9) The power supply are only supply for EIB / KNX system equipment with bus line connection

terminal.

10) Correct Disposal of this product:

This marking indicates that this product should not be disposed with other household wastes

throughout the EU. To prevent possible harm to the environment or human health from uncontrolled

waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return

your used device, please use the return and collection systems or contact the retailer where the product

was purchased. They can take this product for environmental safe recycling.

Summary of Contents for KP/D 30.640.1

Page 1: ...K BUS Power Supply_V1 1 KP D 30 640 1 KNX EIB Home and Building Control System User Manual ...

Page 2: ...ces away from strong magnetic field high temperature wet environment 2 Do not fall the device to the ground or make them get hard impact 3 Do not use wet cloth or volatile reagent to wipe the device 4 Do not disassemble the devices ...

Page 3: ...Contents Chapter 1 Introduction 1 Chapter 2 Technical Parameter 2 Chapter 3 Dimension and Connection Diagram 3 3 1 Dimension drawing 3 3 2 Connection Diagram 4 Chapter 4 Normal Working Test 4 ...

Page 4: ...be installed and used according to national wiring rules 7 For indoor use only 8 The product is not a toy keep it where the children can not reach it 9 The power supply are only supply for EIB KNX system equipment with bus line connection terminal 10 Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes throughout the EU To pre...

Page 5: ...er to facilitate the installation in the distribution box according to the design of EN 60715 it can be installed on a 35mm DIN rail The device is connected with the screw post for electrical connection The bus connection is directly connected through the KNX connection terminal red black The auxiliary power supply is also connected directly through the KNX connection terminal yellow white and the...

Page 6: ...y Green LED ON Output voltage is OK Red LED I Imax Overload or short circuit Reset button SEC Reset at the KNX output starts when the push button is pressed and lasts 22 seconds Red LED Reset at the KNX output Connection Power supply 2 srew terminals Cable cross section Single core 0 2 4 0mm2 Multi core 0 2 2 5mm2 KNX output Bus connection terminal red black Auxiliary voltage output Connection ter...

Page 7: ...K BUS KNX EIB Power Supply 3 Chapter 3 Dimension and Connection Diagram 3 1 Dimension drawing ...

Page 8: ... terminal auxiliary voltage output 5 Mains supply ON Green LED output voltage is OK I Imax Red LED overload short circuit Chapter 4 Normal Working Test When power supply has been correctly installed switch on the main power supply for the bus power and the green LED ON all other LEDs are switched off that is the device function correctly ...

Reviews: