Station No 1 will now be flashing and it will be OFF.
The DiSplay Will ShoW:
This means the pump will not turn on when station No 1
is
running. To turn the pump ON or OFF for a particular station
press the
button so that
“OFF”
is now flashing. Press the
button to turn the
pump ON or press the
button to turn the pump OFF for that particular station number.
Complete this sequence for all station No’s by pressing
and adjust
“ON”
or
“OFF”
with
the
or
buttons.
Pressure buIld
The pressure build system is used to allow the recovery of water supplies and to speed up slow valve
changes within a system.
Basically what happens is, as the controller changes from one valve to another, a system delay is
inserted between valves. In essence, during this delay period, the pump is working against a closed
head. The advantage of this is in systems where the valves are slow to change, it is possible to
speed them up by inserting a delay period and pressurizing the main line. This system can also be
used on wells, where draw down can occur or cavitation of centrical pumps is a problem.
warning:
This option is used to make pumps work against a closed heads. This can lead to pump failure,
pipe splitting and in some cases, explosion of pressure vessels. Understand how to use this option and
consult a professional regarding the use of this option in your system before implementing it.
To access the pressure build option, turn the dial to the
“Set Auxiliaries”
position, press the
button until the following display appears.
The DiSplay Will ShoW:
Press the
or
buttons to increment or decrement
the program number to apply the pressure build time too.
sPecIal FunctIons
Summary of Contents for RPS469
Page 32: ...30 Spare Watering Planner ...
Page 33: ...31 Spare Watering Planner ...
Page 34: ...32 Notes ...