47
7.7 How to Operation
A.
Continuous Working:
1.
Set on the power source by pushing the line switch on the front side of the
generator.
2.
Lift up the puller roller by pushing down the lever
POSITION 1: Lift up the puller roller to insert the workpiece.
POSITION 2: Descend the puller roller to press the workpiece and lower
puller roller for running.
3.
Tread down the foot switch and check whether the ultrasonic vibrate or not.
There will be a sharp HISSING sound, and the loading meter will indicate
below 1.5A when the output knob is set to scale 10. When touching by hand,
slight heat and tingling will be felt on the horn surface, the more pressure
used, the stronger feeling will be.
4.
Tread down the treadle switch, and the roller and horn will rotate with the
ultrasonic vibrations simultaneously.
Summary of Contents for KS-2010
Page 12: ...11 ...
Page 13: ...12 ...
Page 22: ...21 ...
Page 23: ...22 ...
Page 31: ...30 6 4 Wiring Diagram A MAIN WIRING DIAGRAM A 1 KS 72 ...
Page 32: ...31 A 2 KS 85 ...