52
Chapter 9 Maintenance
It is recommended to perform maintenance at least once a week. While performing
maintenance and cleaning the works, please turn off the power.
1.
Please wipe the machine clean when finished.
2.
Purge accumulated water in the filter.
3.
Add the grease and oil to the
shafts, bearings and moving parts.
4.
Check the whether there is leakage in the pneumatic circuit.
5.
Inspect whether the screws on each part are loose or not; if so, fasten them.
6.
Check whether the tooling horn is worn out.
7.
Check whether the working roller is worn out.
8.
Check whether the connector is loose.
Caution:
Because there are high voltage in both generator and Horn-Transducer
mechanism. It is absolutely necessary to switch off the power supply
beforehand. And if it is necessary to take off the cover, this should only
be done by authorized technicians.
Summary of Contents for KS-2010