background image

 
 
 
 
 

  CAUTION                                                                                                       

1.  To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust 

air into spaces within walls or ceilings or into attics, crawl spaces, or garages.   

2.  Take care when using cleaning agents or detergents.   
3.  Avoid using food products that produce flames under the Range Hood.   
4.  For  general  ventilating  use  only.  Do  not  use  to  exhaust  hazardous  or  explosive  materials  and 

vapors.   

5.  To  avoid  motor  bearing  damage  and  noisy  and/or  unbalanced  impellers,  keep  drywall  spray, 

construction dust, etc. off power unit.   

6.  Your hood motor has a thermal overload which will automatically shut off the motor if it becomes 

overheated.  The  motor  will  restart  when  it  cools  down.  If  the  motor  continues  to  shut  off  and 
restart, have the hood serviced.   

7.  For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a 

maximum of 33" above the cooking surface.   

8.  Two installers are recommended because of the large size and weight of this hood.   
9.  This product is equipped with a thermostat which may start blower automatically. To reduce the 

risk  of  injury  and  to  prevent  power  from  being  switched  on  accidentally,  switch  power  off  at 
service panel and lock or tag service panel.   

10.  Use with approved cord-connection kit only.   
11.  Please read specification label on product for further information and requirements.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for K1005

Page 1: ...TIONS FOR DOMESTIC COOKING ONLY Installer Leave this manual with the homeowner Homeowner Cleaning Maintenance and Operating instructions on the coming pages RANGE HOOD ITEM NO K1005 K1005A REFERED MOD...

Page 2: ...ted fans must always be vented to the outdoors 7 Do not use this unit with any separate solid state speed control device 8 To reduce the risk of fire use only metal ductwork 9 This unit must be ground...

Page 3: ...erload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 7 For best c...

Page 4: ...uct fixing support 2 Safety screw ST4mm x30mm 1 Slidery duct fixing support 7 Mounting Screws 4 x 40mm 8 Mounting Screws 4 x 8mm 9 Drywall Anchors 8 holes 2 Washer 4 x12 x1mm 1 Aluminum Flex Duct VENT...

Page 5: ...24 A maximum of 33 above cooktop is highly recommended for best capture of cooking impurities Distances over 33 are at the installer and users discretion INSTALL THE DUCTWORK NOTE To reduce the risk o...

Page 6: ...crews 4x50mm into the anchors and install the hook on the wall as shown INSTALL SLIDERY DUCT FIXING SUPPORT 1 Calculate the final height of the U shaped section drill 2 holes of 8mm on a suitable plac...

Page 7: ...t which is stands on two sides of the motor PREPARE THE HOOD Note On stainless steel hoods carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flues prio...

Page 8: ...er Use drywall anchors provided 4 Measure the height of the glass to the slidery duct fixing support Adjust the height of the chimney according to the height Then use the duct fixing suppor with two s...

Page 9: ...r water Wipe dry with a clean soft cloth to avoid water marks l For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little wa...

Page 10: ...otor will stop 2 Push the Low button the buzzer will buzz once and the motor runs at low speed 3 Push the high button the buzzer will buzz once and the motor runs at mid speed 4 Push the High button t...

Page 11: ...COOL WARRANTY We will warrant this product free from defects in material and quality for one year and motor for 5 years If any problems occur from correct usage please contact the service department f...

Page 12: ...K Star International Group Inc K Star Electronic Appliance Inc Toll Free 800 893 2168 Email info kstarus com http www kstarus com...

Reviews: