background image

 
 
WARNING                                           

 

Note: This range hood must be properly grounded. The unit should be installed by a qualified 
electrician in accordance with all applicable national and local electrical codes.   

 
The minimum hood distance above cooktop must not be less than 24

’’

. A maximum of 33

 above 

cooktop is highly recommended for best capture of cooking impurities. Distances over 33

 are at the 

installer and users discretion.

 

 
 
 
INSTALL THE DUCTWORK 

NOTE: To reduce the risk of fire, use only metal ductwork. 

1.  Deside where the ductwork will run between the hood and 

the outside. 

2.  A straight, short duct run will allow the hood to perform most 

efficiently. 

3.  Install the Aluminum Flex duct on the vent towards hood 

location.   

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

Summary of Contents for K1005

Page 1: ...TIONS FOR DOMESTIC COOKING ONLY Installer Leave this manual with the homeowner Homeowner Cleaning Maintenance and Operating instructions on the coming pages RANGE HOOD ITEM NO K1005 K1005A REFERED MOD...

Page 2: ...ted fans must always be vented to the outdoors 7 Do not use this unit with any separate solid state speed control device 8 To reduce the risk of fire use only metal ductwork 9 This unit must be ground...

Page 3: ...erload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 7 For best c...

Page 4: ...uct fixing support 2 Safety screw ST4mm x30mm 1 Slidery duct fixing support 7 Mounting Screws 4 x 40mm 8 Mounting Screws 4 x 8mm 9 Drywall Anchors 8 holes 2 Washer 4 x12 x1mm 1 Aluminum Flex Duct VENT...

Page 5: ...24 A maximum of 33 above cooktop is highly recommended for best capture of cooking impurities Distances over 33 are at the installer and users discretion INSTALL THE DUCTWORK NOTE To reduce the risk o...

Page 6: ...crews 4x50mm into the anchors and install the hook on the wall as shown INSTALL SLIDERY DUCT FIXING SUPPORT 1 Calculate the final height of the U shaped section drill 2 holes of 8mm on a suitable plac...

Page 7: ...t which is stands on two sides of the motor PREPARE THE HOOD Note On stainless steel hoods carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flues prio...

Page 8: ...er Use drywall anchors provided 4 Measure the height of the glass to the slidery duct fixing support Adjust the height of the chimney according to the height Then use the duct fixing suppor with two s...

Page 9: ...r water Wipe dry with a clean soft cloth to avoid water marks l For discolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little wa...

Page 10: ...otor will stop 2 Push the Low button the buzzer will buzz once and the motor runs at low speed 3 Push the high button the buzzer will buzz once and the motor runs at mid speed 4 Push the High button t...

Page 11: ...COOL WARRANTY We will warrant this product free from defects in material and quality for one year and motor for 5 years If any problems occur from correct usage please contact the service department f...