K-Stove® is a brand of DMS-Europe BV
NL-3641AR-2 The Netherlands
10
(Measured from the outside of the stove)
From non-combustible objects
A > 400 mm B > 100 mm C > 100 mm
From combustible objects and to load-bearing walls in reinforced concrete
A > 800 mm B > 200 mm C > 200 mm
E N G L I S H
ELECTRICAL CONNECTION
The stove is supplied with an approx. 2 m long connecting cable with a plug. The cable
must be connected to a 230 V, 50 Hz electrical supply. The average electric power
consumption is approx 100 watts during heating. During the automatic ignition process
(duration 10 minutes) approx. 350 watts. The connection cable must be laid so that any
contact with hot or sharp-edged external surfaces on the stove is avoided.
COMBUSTION AIR
Each combustion procedure requires oxygen or air. As a rule this combustion air is removed
from the living area for individual stoves The air taken from the living area must be
reintroduced. In modern houses, very tight fitting windows and doors mean that too little air
flows back. This situation becomes problematic due to additional ventilation in the house (e.g.
in the kitchen or WC).
The suctioning in of combustion air is performed via the flue gas blower. The resulting
combustion air and suctioning noises are normal operational noises
that may occur at varying volumes depending on the chimney draught, output level or a dirty
combustion trough – NOT A CAUSE FOR COMPLAINT!
Feed of external combustion air
●
Steel, HT or flexible aluminum pipes must be used.
●
Minimum diameter 5 cm/2 inches.
●
For longer connection runs, the diameter must be increased to approx. 10 cm after approx.
1 m.