K-Stove® is a brand of DMS-Europe BV
NL-3641AR-2 The Netherlands
36
piled pellet, carbon on the
glass
burning.
Check the door and window glass
gasket sealed or not.
Check the air intake pipe and
venting pipe blocked or not, and
clean it. Change to the big diameter
pipes if pipes are too long to affect
combustion.
Adjust the combustion fan's speed
up
Call the dealer to reset the program
7 The fire put out and
power is off
automatically.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
low temperature switch
(30˚C) is wrong.
Set temperature is
reached
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30˚C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again
8 The blower still works
after the stove is cool and
fuel feed stops.
The low temperature
switch (30˚C) is broken.
Change this switch.
9 no enough heat wind
Unqualified fuel
Blower speed is too low
or not running.
Heat exchange tubes or
flue pass are dirty.
Use the standard specially pellet.
Change the blower(Broken) or the
mother board is broken
Clean the heat exchange tubes or
flue pass.
10. Showing "E5" on the
display
Vent pipe is blocked
Shut down the stove, check the
venting pipe