background image

 

 

K-Stove® is a brand of DMS-Europe BV                                                                                                   

NL-3641AR-2 The Netherlands 

37 

The door is opening or 

seal needs to be replaced 

 

The are some leakages 

 

Close the door or change the seal 

Check it and repair it. 

Adjust the combustion fan's speed 

up to offer more pressure in the 

stove 

ELECTRICAL GENERATOR OPERATION 

Your stove can be powered with a gas driven electrical generator. 

However, the generator’s electrical regulator may not be compatible with the stove’s 

electronics. The higher the quality of the generator, the greater the chance that it is 

compatible with the stove. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for EN 14785

Page 1: ...E EN 14785 BImSchV Stufe 2 certified by TÜV SÜD Germany A LIFETIME OF WARMTH Please read this entire manual before installation and use of this pellet fuel burning room heater Failure to follow these instructions could result in property damage bodily injury or even death Save these instructions INSTALLER THIS MANUAL MUST STAY WITH APPLIANCE ...

Page 2: ...3641AR 2 The Netherlands 2 Table of Contents 1 Fuel Requirement 3 2 Stove Features 4 3 Structure instruction 5 4 Pellet Stove Installation 7 5 Operation 11 6 Cleaning and Maintenance 26 7 Troubleshooting 30 8 Warranty 35 9 Electronic Plan 36 ...

Page 3: ...In order to guarantee problem free burning of the wooden pellets it is necessary to store the fuel as dry as possible and free from impurities This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person ...

Page 4: ... 463x771x549 Weight NET GROSS KG 110 130 95 110 85 100 Air inlet Pipe MM 50 50 30 Air outlet Pipe MM 80 80 80 Heating Performance range KW 3 8 11 5 3 7 6 3 6 Room heating capacity m3 dependent on house insulation M3 60 300 60 220 60 120 Consumption for Pellet Min Max KG H 0 6 2 5 0 5 1 75 0 4 1 15 Pellet container capacity KG 28 18 15 Automatic Burning Time Min Max H 17 37 10 5 36 13 37 Power supp...

Page 5: ...over 7 Side Panels 8 Chamber Insulation cover 9 Shoulder 10 Hot wind driver 11 Motherboard 12 Fire pot 13 Vacuum Switch 14 Igniter 15 Combustion fan 16 Blower 17 Rear Cover 18Bottom Clear cover 19 top clear covers 20 Display 21 exhaust connection 22 Power input socket contains the main fuse 23 Room temperature Sensor 24 Handle 25 Stove adjustable Feet 26 fire chamber 27 Safety temperature Sensor 2...

Page 6: ...d the left door fastened to the base If a low pressure is created in the firebox by a leak opening the front door a blocked flue or unsealed ash drawer the vacuum switch will sense it and cause the heater to go into a shutdown mode AUGER AND AUGER MOTOR The 2 RPM auger motor turns the auger lifting pellets up the auger tube The pellets are then dropped down a tube and into the firepot The auger is...

Page 7: ... is approved for solid fuels The chimney must have a diameter of at least 80 mm The flue system is based on negative pressure in the combustion chamber and a slight overpressure on the flue gas outlet It is therefore important that the flue gas connection is fitted correctly and is airtight Only use heat resistant sealing materials as well as the relevant sealing bands heat resistant silicon and m...

Page 8: ...mney are not too long Avoid too many changes of direction for the flue gas flow to the chimney e g too many corners and bends Where you cannot connect directly to the chimney if possible use a connection piece with cleaning opening For optimum efficiency please use the type of connector we recommend MAKING THE CHIMNEY CONNECTION Horizontal ...

Page 9: ...aw the chimney connection taking any floor plate thickness into consideration 2 Chisel out drill the hole in the wall 3 Brick in the wall lining 4 Connect stove with the flue tube to the chimney FLOOR PROTECTION For flammable floor surfaces wood carpet etc a glass steel plate or ceramic underlay is required SAFETY DISTANCES ...

Page 10: ...s avoided COMBUSTION AIR Each combustion procedure requires oxygen or air As a rule this combustion air is removed from the living area for individual stoves The air taken from the living area must be reintroduced In modern houses very tight fitting windows and doors mean that too little air flows back This situation becomes problematic due to additional ventilation in the house e g in the kitchen...

Page 11: ...dent of the room air Negative pressures in the set up room are not permissible Therefore the use of a safety device e g differential pressure controller in combination with room air facilities e g ventilation system exhaust extraction etc is stipulated 5 Operation ALL NATIONAL AND LOCAL REGULATIONS AND EUROPEAN STANDARDS SHALL BE COMPLIED WITH WHEN OPERATING THE APPLIANCE Attention When the stove ...

Page 12: ... power is on Operate as the instruction on section start and operation Start and operation USERS GUIDE Please operate the stove as following refer to stove structure figure and electrical control figure Check the box pellet grate bar ash pan then adjust to proper position ...

Page 13: ...K Stove is a brand of DMS Europe BV NL 3641AR 2 The Netherlands 13 1 Operations Instructions Quick reference guide ...

Page 14: ...previous one and then In the same way push then at the switching off Period the message shows Thirdly After second phase is showed from the message FEEDING In this phase are performed the chimney verification operations and the pellets will be loaded in the melting pot The successive phase will be showed from the inscription Lighting This state remains up to when the smokes temperature doesn t exc...

Page 15: ...ng stabilization How to make the stove immediately skip the process to Stabilization During the first several stages when you think the flame is ok and or the stove can work properly Push for 3 seconds and then it will turn on Stabilization directly ATTENTION If the heater is switched off the flame will continue to be present up to the fuel exhaustion contained in the melting pot this phase will m...

Page 16: ...the heating desire fuel intake quantity can be adjusted from few to large by the fuel intake Button For example Pressing the key the feed quantity can be changed the display shows the selected power MINIMUM POWER P4 LOW POWER P3 MEDIUM POWER P2 MAXIMUM POWER P1 ECO STAGE If the room temperature exceeds the set out temperature automatically the stove is stopped Eco1 or turns to minimum power in ord...

Page 17: ...nual DESIRED TEMPERATURES SETTING Pressing the keys on the display The temperature is selecting How to Check the Room temperature Exhaust Smoke Temperature Safety Protection Temperature which is located under the hopper By Push button The number with R is the temperature for room The number with S is the temperature for the Smoke The number with P is the temperature for the Protection For example ...

Page 18: ...K Stove is a brand of DMS Europe BV NL 3641AR 2 The Netherlands 18 3 How to set details Setup Quick reference guide ...

Page 19: ...K Stove is a brand of DMS Europe BV NL 3641AR 2 The Netherlands 19 ...

Page 20: ...m Both of them can be adjust from 20 to 20 Normally Factory setting is 0 20 is max and 20 is min Press to save the setting and go to P2 and P3 and P4 as following After P4 it is P5 this data is related to the exhaust fan s speed of the Cleaning stage The adjustable range is also from 20 to 20 The following is P6 this data is related to the exhaust fan s speed of the Feeding Lighting and some minut...

Page 21: ... Keep Pressing it shows FTF FRIST TIME FEEDING 75 2 S MEANS 150 SECONDS FEEDING TIME You can adjust thee time by pressing CLOCK SETTING Press the key the time can be amended You can select week or time by keys also using to change the day or time to save the correct data by press and move to next stage ...

Page 22: ...ter for a weekly programming associating the switching on and the switching off at the pre fixed timetables You can program daily switching on and switching off for the whole week By keeping pressing the key you will found the attached instruction above Then you can press to choose week days By pressing to select hours then press to decide the hour on or Off On the above line it is showed the day ...

Page 23: ...pressing the key ECO mode SETTING By keeping pressing the key it will appear the following words Pressing the key to select the Mode 1 or Mode 2 Mode 2 is for turning to minimum Power while mode 1 is for stopping the stove Restore Defaults select Keeping pressing the key it will appear the following words By you can choose Yes Or No Yes go back factory setting NO use the data you have changed ...

Page 24: ...r is broken It means there is earthquake during the operation time or You tilt the stove Only for the Japan version Problem for the temperature sensor Unplug or broken or water temperature is too high This function only for the pellet stove with hot water It means that there are some problems with vacuum Switch Such as door has not been closed properly Combustion fan s speed cannot Speed up There ...

Page 25: ... open circuit It means temperature sensor 3 sensor for testing the room temperature which is located on the rear panel is short circuit It means temperature sensor 3 is open circuit 4 Safety POWER FAILURE After the power failure the display will be show E7 If short power failure you can do manually goes back to Stabilization by Clear the E7 by okay button restarting the stove and then keeping pres...

Page 26: ...e auger tube The pellets are then dropped down a tube and into the firepot The auger motor is controlled by the control board PROTECT TEMPERATURE SENSOR TO AVOIDOVERHEATING A safety temperature switch switches the stove off automatically if it overheats After the stove has cooled down meanwhile it shows E6 Whether the heating operation is continued or not depends on the remaining embers in the fir...

Page 27: ...se High moisture contents ash dust and chips can more than double the necessary maintenance intervals We would like to point out once again that you should only use tested and recommended wooden pellets as a fuel Operating handle Your new pellet stove comes with an operating handle that is used for opening or closing the grate door Please use this operating handle for Cleaning the fire pan Looseni...

Page 28: ...s correctly seated CLEANING THE GRATE DOOR GLASS The best way to clean the grate door glass is using A damp cloth with small amount of ash from the firebox Stubborn dirt can be removed using a special cleaner that can be purchased from your specialist stove dealer CLEANING THE FLUE GAS PASSAGE WAYS Cleaning the flue passageways should be done at least once a year Burning high ash pellets may requi...

Page 29: ... holes located behind the ash drawer Remove the ash drawer see the previous page and loosen the two 5 32 allen head screws shown as D in the drawing below Rotate the covers over the access holes and use a brush and vacuum to clean the ash Rotate the covers back over the holes and tighten the screws Front View Looking into the Ash Drawer Cavity with the Ash Drawer Removed HOW TO CLEAN THE STOVE ...

Page 30: ...T PIPE Soot and Fly ash Formation and Need for Removal The products of combustion will contain small particles of fly ash will collect in the exhaust venting system and restrict the flow of the flue gases Incomplete combustion such as occurs during start up shutdown or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system The exhau...

Page 31: ...100 bags NOTE Cleaning schedule will vary depending on quality of pellets used Burned high ash pellets used Burned high ash pellets will require more frequent cleaning We do advise to use only certified pellets as mentioned on page 3 Burn only pellets that have been tested and certified with EN A1 plus ask your dealer for advise ...

Page 32: ...K Stove is a brand of DMS Europe BV NL 3641AR 2 The Netherlands 32 7 Troubleshooting HOW TO REPLACE INGITION BAR AND AUGER SYSTEM HOW TO REPLACE THE ROOM FAN BLOWER ...

Page 33: ...K Stove is a brand of DMS Europe BV NL 3641AR 2 The Netherlands 33 HOW TO REPLACE THE COMBUSTION FAN The general troubles the possible reasons and the solutions are as following after solving ...

Page 34: ...ing the start bottom If after stabilization it doest work there must be wrong It is normal It will start automatically when the temperature is above 30 degrees on the venting pipe Please wait No power in stove or in the control panel Or Unplugged on the mother board The low temperature sensor is broken Check the power and wires Plug it Replace it 3 No feeding after 20 seconds of starting There are...

Page 35: ...m about the connection between motor and auger Check the fasten screw between auger and motor loose or not Or the auger might jump out No fuel in the hopper Fill the fuel into the hopper 4 Feeding not properly A too much wood pellet and cannot burned in time The level of feeding speed is too high Adjust the combustion fan s speed up or Feeding quantity B The fire is off due to little wood pellet c...

Page 36: ... is reached Put fuel into the hopper refer to 2 Lower the speed of combustion fan Cool the stove at least 1 hour then operate again or change the low temperature switch 30 C ECO its normal waiting after the temperature is blow set on it will automatically switch on again 8 The blower still works after the stove is cool and fuel feed stops The low temperature switch 30 C is broken Change this switc...

Page 37: ...t and repair it Adjust the combustion fan s speed up to offer more pressure in the stove ELECTRICAL GENERATOR OPERATION Your stove can be powered with a gas driven electrical generator However the generator s electrical regulator may not be compatible with the stove s electronics The higher the quality of the generator the greater the chance that it is compatible with the stove ...

Page 38: ...ed properly according to the Instructions for Use valid at the time of purchase Connection must be performed by a specialist for such stoves The warranty excludes WEARING PARTS such as glass coating surface coatings e g handles panels seals fire trough grates draught plates deflector plates combustion chamber liners e g fireclay ceramics natural stone ignition elements sensors combustion chamber s...

Page 39: ...K Stove is a brand of DMS Europe BV NL 3641AR 2 The Netherlands 39 9 Electronic Plan ...

Page 40: ...reland by Doyle s Importers and Distributors Shamrock Commercial Park Dublin Road Castlecomer Co Kilkenny Tel 353 56 444 1988 Fax 353 56 444 1978 Freefax 1800 200 650 E sales doylesw ie W www doyles ie Your dealer is Do Not forget to register your K Stove pellet stove via http www kstove com kstove register ...