3.1.2
ON-OFF Battery Switch
It allows the user to switch the robot ON or OFF. When ON, the robot is
powered. The robot may even be powered without the battery pack using
the external power supply connector. See figure 3.1 number 7.
3.1.3
Indication LEDs
The Khepera III has six indication LEDs, two for the battery charger, one
for the Power ON, one for the state of the motors controller and two pro-
grammables by the end-user (see figure 3.2).
When the Motor controller state LED is on, one of the two motor con-
troller is in error mode. This could append when a motor is blocked or
a current limit is detected. In this case the controller must be reset by
the dsPIC (’M’ command in serial interface mode or call ’initKH3()’ in a
KoreBotLE program).
For the battery charger, the red one indicates that charge is in progress
and the green one signals when the charge is complete. If there’s no battery
pack when you plug an external power supply, the green one will turn on.
The led 5 and 6 can be set by the user with ’L’ command. See annexe
A Serial communication protocol.
Figure 3.2: LEDs of the Khepera III.
1. Motor Controllers state LED (redD).
2. Power ON LED (green).
3. Charge completed LED (green).
4. Charge in progress LED (red).
5. Programmable LED (green).
6. Programmable LED (red).
Khepera III manual ver 2.2
8