5.2
Testing the secondary serial link
As the robot is suited to be used with a KoreBotLE it is important to test
the serial link between the host computer and the KoreBotLE itself.
- Make sure all connections are correct (see chapter 4 for details).
- The robot should be placed on a flat and safe surface. The battery
switch must be OFF.
- A KoreBotLE needs to be plugged on the appropriate socket.
- A terminal emulator should be running on the host computer. Make
sure the terminal is connected to the correct serial port.
The termi-
nal configuration must be set to 115200 Baud, 8 bit, 1 start
bit, 1 stop bit, no parity and no hardware control
.
When powered on, the KoreBotLE will send the normal linux boot mes-
sage to the terminal emulator (see fig 5.2).
If any of the serial link is not working properly it is then important to
ensure that the serial communication settings has been configured correctly.
Figure 5.2: Boot message of the KoreBotLE.
Khepera III manual ver 2.2
27