quantities of product than the suggested formula. Keep a record of the
measured pump flow rates in the chart below or one similar.
Pump Number
Flow Rate
Pump Port 1 Flavor
oz/sec
Pump Port 2 Flavor
oz/sec
Pump Port 3 Flavor
oz/sec
Pump Port 4 Flavor
oz/sec
Pump Port 5 Flavor
oz/sec
Pump Port 6 Flavor
oz/sec
Pump Port 7 Flavor
oz/sec
Pump Port 8 Flavor
oz/sec
7.2
Water Flow Rate:
Calibrate Water flow rate in much the same way as you calibrated the pumps.
7.2.1 With all data sets of Drink 1 at “0”, press the GO or L pad until the display
reads: “Drink 1 Watr 0”.
7.2.2 Press 5-0-GO and then STOP twice.
7.2.3 Press
S-1-GO.
7.2.4 Measure the water in the jar and divide by 5 to get the water flow rate.
E.g. With 2.5 oz. of water in the jar, 2.5/5 = 0.5 oz per second.
Record
this number. Because the water comes from the same valve for all drinks,
the water flow rate will be the same for every drink.
7.3
Ice Temperature Range:
The Ice level sensor notifies the user when the ice hopper is close to being empty.
7.3.1 The sensor can be disabled or enabled by pressing 3-5-8-GO. The display
will either read, "Ice Sensor On" or "Ice Sensor Off". Pressing S or M will
make a selection.
7.3.2 Once the mode of operation is selected, press the GO button to advance to
the temperature setting of the Ice Sensor. The display will read, "Low Ice
Temp 10C". This setting is the temperature at which the sensor turns on
the Low Ice LED (light on the control panel).
7.3.3 This value can be changed by using the numeric keypad to enter a new
temperature and by pressing GO. If 10 degrees C is selected as the Low
Ice Temperature then the ice full temperature will be 8 degrees C.
7.3.4 A current temperature reading is displayed by pressing GO after the Low
Ice Temp has been entered.
7.3.5 Press STOP to exit the menu.
7.3.6 It may take up to 20 minutes for the temp in the hopper to stabilize and for
the REFILL ICE reminder to disappear.
OWN-003 Model BDI Owner’s Manual – Blender Dispenser with Ice