OPERATION
20
Touch the “
CYCLE TYPE
” tab to select a cycle either by time or by product temperature core probe:
In order to modify the cycle options, press into the tab of the option that need to be adjusted . The
tab will light green then dial the value using the keyboard on the right side of the screen. Once set
up the correct value, press the OK button.
By factory default, the AIR TEMP. is -40°C, the fan speed is 10 and the storage temperature is
-40°C.
Once set up the cycle options touch the
START
button to start up the cycle: the controller will start
to load the program and a message will be displayed on the screen: