background image

STANDARDS AND GENERAL WARNINGS 

11 

1.8  ORDERING OF SPARE PARTS 

  Orders of spare parts should be made by consulting the part reference code and the serial 

number of your unit. Consult your dealer. 

1.9  PRODUCT CONFIGURATION 

  The  unit  is  designed  solely  for  the  preservation  of  laboratory  products,  which  requires 

various controls and warning in case of sudden alteration of temperature. 

 

PRODUCTS  MUST  BE  STORED  IN  ORDER  TO  ENSURE  EFFICIENT  AIR 

CIRCULATION  INSIDE  THE  UNIT  AND  SHALL  NOT  COME  OUT  OF  THE 
SHELF/DRAWER PERIMETER. 

  All  uses  outside  of  manufacturer’s  intended  use  in  section  1.1  shall  be  construed  as 

“improper use” for which the manufacturer declines all responsibility. 

  It’s allowed to accommodate on the shelf a maximum of 20kg per shelf in according to the 

UL471

  regulation.  [

The  most  critical  application  in  terms  of  weight  (glass  door/  stainless 

steel) has been tested following the Base standard UL 61010-1.The application can contain 
a maximum of 15 shelve.

  

1.10  MATERIALS AND REFRIGERANTS 

  Materials  in  contact  or  potentially  in  contact  with  products  are  in  compliance  with  the 

relevant directives. The equipments designed and built so that contact parts can be cleaned 
before each use. The refrigerants utilized comply with established regulations. 

1.11  WARNING LABELS 

Electrical Shock 

LABEL A 

Use  of  this  equipment  involves  power  supplies  which  convert  line 
voltage to low voltage power. Do not modify or use power supplies 
other  than  OEM  equipment.  Connection  of  the  power  supply  may 
require  a  properly  grounded  receptacle.  Potential  for  electrical 
shock or equipment damage exists if precautions are not followed. 

Hot Surface 

LABEL B 

Avoid contact with the hot surfaces potential for skin’s burns. 

Cold Surface 

LABEL C 

Avoid contact with cold freezer surfaces potential for cold burns or 

skin sticking to cold surfaces. 

Safety Alert 

LABEL D 

Summary of Contents for K215SDF-BB-BF

Page 1: ...Use and Operational Manual Blood Bank...

Page 2: ...efrigerators only if The operations of setting change and repair must be performed by authorized personnel The electrical installation has been carried out in conformity with the instructions The devi...

Page 3: ...LS AND REFRIGERANTS 11 1 11 WARNING LABELS 11 1 12 FDA LABELS 14 2 INSTALLATION 16 2 1 TRANSPORTATION AND HANDLING 16 2 2 POSITIONING 16 2 3 WIRING AND ELECTRICAL HOOK UP 17 2 4 SET UP OPERATIONS 17 2...

Page 4: ...3 2 5 Access the source HACCP files for own purpose 27 4 TROUBLESHOOTING 29...

Page 5: ...C 40F Factory pre set to 40 C 40 F Models K215SDF BB BF Environmental Operating Conditions Nominal environmental operating condition Climatic class 4 30 C HR 55 Ambient temperature operating range 10...

Page 6: ...body This Product is not intended for long term storage Registration This medical application is considered a Class II medical device by the FDA If the equipment is used in a manner not specified by t...

Page 7: ...rs installer user routine maintenance technician service engineer 1 3 PRODUCT DESCRIPTION The equipment comprises a single body with paneling in various materials and insulation with expanded polyuret...

Page 8: ...ctions switch off the equipment and do not attempt to repair it by yourself as doing so may void the warranty All service and repair operations must be performed exclusively by a manufacture s authori...

Page 9: ...weight glass door stainless steel has been tested following the Base standard UL 61010 1 The application can contain a maximum of 15 shelve 1 10 MATERIALS AND REFRIGERANTS Materials in contact or pote...

Page 10: ...instructions To reduce the risk of injury or poor performance of the unit read the user manual before putting the equipment into operation Warning Indicates an immediately hazardous situation which i...

Page 11: ...if not avoided may result in minor to moderate injury Battery LABEL E Indicates the location of the back up battery Grounding LABEL G Indicates that the electrical components are electrically grounded...

Page 12: ...if the Package is Brocken Don t use if the package of the medical Device is broken of Opened This Medical Device has not undergone a sterilization process Read The instructions before the use of the...

Page 13: ...le the lower one is 10 It indicate the model of the Medical Device Is the identifier of the production batch Is the manufacturer internal code It consent to identify a specific Medical Device STANDARD...

Page 14: ...ipment is secured to a wooden pallet base wrapped in a plastic film and packaged into a three waves carton box The equipment must be handled using a fork lift truck or a pallet truck with suitable for...

Page 15: ...t must be suitably located and easily reached it must be marked as the disconnecting device for the equipment The emissions characteristics of this equipment make it suitable for use in industrial are...

Page 16: ...at one of the recycling centers nominated by your Local National Health Department or as specified by the law in force Scrapping and disposal of the equipment must be carried out in full observance o...

Page 17: ...t from those described hereunder It cannot be used as a safely device Check the application limits before proceeding Safety precautions Check the supply voltage is correct before connecting the instru...

Page 18: ...tab will light green then dial the value using the keyboard on the right side of the screen Once set up the correct value press the OK button By factory default the AIR TEMP is 40 C the fan speed is...

Page 19: ...he CYCLE TIME tab Once the CYCLE TIME is elapsed a checkered flag will appear on the screen and a buzzer will start to sound alarming that the cycle ended At the end of the cycle the unit will switch...

Page 20: ...Date Time settings menu the Language set up menu the USB options menu LAN network settings menu I O STATUS menu and the Manual Defrost start cycle 3 2 1 USB option Through the USB port located on the...

Page 21: ...tput menu allow to check all incoming signals such as temperature sensors door switch status the relays status 3 2 3 HACCP download This controller is capable to export HACCP information to a USB key...

Page 22: ...el like shown in the below example Every file represents a single cycle and is encoded as per below scheme 3 2 4 Using a property Software to trace HACCP data The above csv files can be easily loaded...

Page 23: ...order to run games or other graphical interactive application When this software is existing on a PC the file BlastChillerTracer will be automatically associated to the JAVA icon Should this not happ...

Page 24: ...ad File tab on the right top of the screen A search file window will open requiring to find the file indexCycle arg in the haccp folder This is the folder extracted from the haccp zip file downloaded...

Page 25: ...down to zoom in and out To zoom in a specific area of the graph just select the area with the mouse 3 2 5 Access the source HACCP files for own purpose The tracer software is a powerful tool to graph...

Page 26: ...ell format to Number in order to show the time properly Reduce decimal places to 0 Next page will show an example of how the rows should appear and how to read the information DD MM YY HH MM SS PRODUC...

Page 27: ...CES The door is open for more than the allowed time during a cycle Head pressure is too high exceeding 29 barg 425psig Check for clogged condenser condenser fan motor not running or pump down valve no...

Page 28: ...er is a differential of the setpoint HIGH TEMPERATURE It occurs when during the holding cycle the air temperature goes above the higher temperature limit parameter ALH This parameter is a differential...

Page 29: ...CODE DETAILS When an alarm occurs an alert icon will blink on the left upper corner of the screen and the buzzer will activate Click on the alarm icon to see details A message box will appears with t...

Reviews: