background image

Installation and Operation

2

K205ULT Operating Manual

Assembly

• Remove the appliance from the packaging          

and peel off any protective film from all   

 

surfaces.

• Ensure that this product is positioned on a 

level surface, so as to allow the door(s) to shut 

and seal correctly, as well as to allow proper 

drainage from the evaporator tray, to prevent 

any overflow.

Ventilation

• All models must have clear and unobstructed 

ventilation from the entire surface area of the 

front grille.

Temperature Controller

3

SET

RST

- Enter a parameter setting  

- Switch between menu and parameter

- Adjust menu and parameters

- After 3s, parameter setting downloads

- Adjust menu and parameters

- After 3s, parameter setting uploads

- Exit from parameter settings

- Press for 3s to force stop capillary 

heating output

- Cleat alarm

- The mandatory cooling mode will be 

activated or 10s

Power and Contacts

3

Summary of Contents for K23ULT

Page 1: ...arameters may damage the unit or void your warranty Please contact K2 before attempting to change advanced parameters Unfamiliar with the operation of a controller Use the video tutorials on our websi...

Page 2: ...must be performed by qualified service personnel Do not use this appliance for other than its intended use Do not cover the front grille or block the rear air entry by placing object up against the ca...

Page 3: ...to prevent any overflow Ventilation All models must have clear and unobstructed ventilation from the entire surface area of the front grille Temperature Controller 3 SET RST Enter a parameter setting...

Page 4: ...sor stop High temperature compresso time delay Low temperature compressor work in non forced refrigeration mode Low temperature compressor is closed in non forced refrigeration mode Forced refrigerati...

Page 5: ...ger 15 0 15 0 0 C9 Condenser probe calibration High temp compressor loop 15 0 15 0 0 C10 Ambient temp probe calibration 15 0 15 0 0 C11 High temp evaporator probe calibration 15 0 15 0 0 C13 The Minim...

Page 6: ...K205ULT Operating Manual Product Description 5...

Page 7: ...K205ULT Operating Manual Maintenance 6 Alarm Code...

Page 8: ...Contact us via our chat feature at www k2sci com 2 Email support k2sci com 3 Call 800 218 7613 When storing vaccines you may be required to preform a field validation test A NIST callibrated external...

Page 9: ...0 0 40 C15 Maximum temp of high temp evaporator when low temp compressor turned off C7 10 0 12 H1 The cycle time of capillary heating wire 1 300 108 H2 The working time of capillary heating wire 1 90...

Reviews: