* Read and understand all instructions before you use your product. 

* Warranty does not apply if damage was caused by failure to follow instructions.

* Only use the alkaline batteries.

* Do not expose the product and accessories to rain or water.

* Do not expose the product to corrosive substances so as not to damage the protective cover.

* Do not scrape the fingerprint sensor with sharp objects, otherwise it may cause permanent damage.

* When cleaning the product, please wipe with a soft cloth.

* If there is a low battery alert, please replace all the batteries in time and make sure they are properly installed.

Warning

1. You can operate following the voice guide by multi-language
   (Chinese/English/Spanish/Portuguese/ Russian).
2. Master PIN Code(6~12 digit): Default master PIN code is “12

   345678”, please modify  it after installation.

3. User PIN Code(6~12 digit): Maximum capacity is 10 with user
   number [00-09].

Touch screen keypad

Card reader area

Fingerprint sensor

Fingerprint sensor

4. Temporary user PIN code (6-12 digit): there is only one 
    temporary user PIN code.
5. Card: Maximum capacity is 100 with user number [00-99].
6. Fingerprint: Maximum capacity is 20 with user number
    [00-19].

Definitions

Specifications

Preparing for Installation

Components

Installation

Outside escutcheon

Inside escutcheon

1

2

3

6

4

5

www.kaadasgroup.com

Shenzhen Kaadas Intelligent Technology Co., Ltd reserves all rights 

for the final interpretation to this user manual

All design and specifications are subject to change without notice.

1.Check whether the door is left handed or right handed before installation.

1. Get the front escutcheon cable through the drill

    hole on the door.

4. Get the outside escutcheon cable connected

    to the inside escutcheon.

3. According to the actual installation height of the 

    lock, select the number of strike shims to be 

    installed, and fix them together with the strike.

    After installing the strike,secure the  strike cover

    with the 2 mounting screws.

2. Get the front escutcheon cable through the 

    inside mounting plate and fix screws from

    inside of the door. 

* Be careful not damage

  the connecting cable

2.Comfirm inside escutcheon installation direction.

3.Based on door type and direction, match and

   hold installation template on door tightly and

   drill a hole on door.

left handed door

left handed door

right handed door

right handed door

Outside

Outside

Master Mode: 

The Master Mode could be entered by entering “#+Master PIN Code+#” to programming the lock.

Master PIN code:

The Master PIN Code is used for unlock, programming and setting feature. The default Master PIN code[12345678] is 
required to be changed immediately after enter the menu at the first time.

Auto Re-lock:

After unlocking successful by PIN Code/Card/Fingerprint/APP, it will automatically lock in auto re-lock mode once the door is 

closed.

One-Time PIN Code:

This code can only be used once and will be automatically deleted after using.

Manual Mode:

Auto re-lock mode could be adjusted to Manual Mode. In Manual Mode the lock could be locked by verifying user 
code/fingerprint/card from outside.

Silent Mode:

Enabling Silent Mode shuts off the code confirmation tone playback for use in quiet areas. Silent mode is selected in the 

voice setting of Master Mode.

Status LED:

Located on outside escutcheon.

Lockout Mode:

When wrong user PIN code/card/fingerprint for 5 times,the system will lock down for 3 minutes.
After that the lock will activate again. while the lock is lock down, the system will alarm when you are trying to use keypad.

Away Mode:

It is a security feature when you are leaving home for vacation or a long trip. If the lock is unlocked by the key or by the 

thumbturn in away mode, the lock will sound an alarm.

Dual-verification Mode:

Any combination of fingerprint, PIN code and card can be flexibly used.

Reset button:

After reset operation, the lock will be restored to factory default settings, all user credentials will be deleted. Refer to reset guide.

Menu Table

7

X3

X3

X6

Strike shims

Strike shim

Strike cover

Outside escutcheon

Inside escutcheon

Flat Head Screws M5*40mm

(Door Thinckness 40-50mm)

Flat Head Screws M5*30mm

(Door Thinckness 30-40mm)

Wood Combination screws

ST4*20mm

Mounting Screws

M4*6mm

Inside Mounting Plate

Strike

6

6 9 m m

20

0.3

m

m

77.3mm

Dead bolt

Battery cover

left handed door

Edge the door

Inside

Inside

right handed door

Auto-Relock mode

and manual mode

switch

6. Fix battery cover screws after insert 4AA

    batteries and test functions.

5. Get the inside escutcheon on the bracket and

    fix screws.

1.Modify Master PIN code

2.User Setting

3.Delete Users

4. System Setting

5. Extended Function

6. System Query

7. Bluetooth Setting

Press

[3]

1. Delete User PIN Code
2. Delete Temporary PIN Card
3. Delete Fingerprint
4. Delete User Card

Press

[4]

1. Language Setting

2. Volume Setting
3. Opening Mode Setting

Press

[5]

1. Join the Remote Network
2. Exit the Remote Network

Press

[6]

1. Query Serial Number
2. Query Firmware Version

Press

[7]

1. Enable Bluetooth

Press

[1]

Modify Master PIN code

Press

[2]

1. Add User PIN Code
2. Add Temporary PIN Card
3. Add Fingerprint
4. Add User Card

Type C USB emergency

power supply

1. Delete a Single User PIN Code
2. Delete  Codes

1. For adding front lock fingerprint
2. For adding rear lock fingerprint

1. For deleting front lock fingerprint
2. For deleting rear lock fingerprint

1. Delete a Single User Card
2. Delete Cards

1. Chines     2. English     3. Portuguese
4. Spanish

    

5. Russian

1. High Volume    2. Low Volume   

3. Silent mode

1. Single -verification Mode
2. Dual-verification Mode

Reviews: