background image

1

I

NTRODUCTION

The X-09 uses sophisticated computer security and makes dialing much easier than that of 
traditional combination locks. The microprocessor in the lock recognizes a number as part 
of a combination when you change dialing direction. (See the section on Dialing the X-09.)

Note: 

The lock is shipped preset to operate in the Single Combination Mode with 

Default Factory Combination

 of 50-25-50. 

 

 

 

LOCK ON BACK COVER

The Lock On Back Cover (LOBC) feature provides a locking mechanism that locks the back 
cover in place after installation. The design is such that the back cover cannot be removed 
without visible damage unless the combination is known, regardless of whether the lock is 
locked or unlocked.

Note: 

The 6-digit lock serial number is located in 2 places on the lock. 

The first location is in the form of a removable sticker on the back 
cover (see Figure 1), which is designed for the security professional 
in charge of this lock to peel off and place on the proper form. The 
second location is on the electronics card, next to the super-capacitor, 
in the form of a permanent label also showing a barcode (see Figure 2).
  Since you may need the serial number of the lock to reset it if the 
combination is lost or forgotten and the door is open, it is important 
that you keep a record of the lock serial number in a secure place.
  Because of the LOBC feature, it is not an easy task to remove the back 
cover to read the lock serial number after the 
lock is installed. If you do not have the serial 
number from the removable label, follow the 
procedure below to remove the back cover 
and retrieve the serial number.

To Remove the Lock on Back Cover:

1. Dial the combination(s) to open the lock and then
  retract the bolt.

2. Release the container locking bolts.

3. Open the container.

4. Remove the dust cover plate.

5. Locate the lock on back cover pin on the back
  cover of the lock case. (See Figure 1)

6. Turn the dial to the 

left

 to extend the bolt. Do not 

  close the container.

7. Dial the combination(s) to open the lock.

8. Before turning the dial to retract the bolt, pull out
  on the unlocking button.

9. While holding the button out, turn the dial to the
 

right

 to retract the bolt to the unlocked position.

10.  Remove the back cover screws.

11.  Remove the back cover assembly.

12.  Look at the label next to the round super-capacitor on the system card to get the lock
    serial number. (See Figure 2)

Figure 2 - Serial # on label

next to capacitor 

Figure 1 - Lock On Back Cover 

Lock On Back

Cover Pin 

Serial Number

Sticker

Summary of Contents for 1F

Page 1: ...OPERATING INSTRUCTIONS X 09TM Type 1F HIGH SECURITY ELECTRONIC LOCK ...

Page 2: ...Lock 4 X 09 LOCK SETUP 5 Set Operating Mode and Change Combinations 5 If You Lock the Change Key in the Safe 8 USING THE X 09 9 Single Combination Mode 9 Dual Combination Mode 9 Supervisory Subordinate Mode 10 Correct Method of Closing Relocking Container 11 AUDIT FEATURES OF THE LOCK 12 To Check the Number of Successful Openings 12 To Check the Number of Unsuccessful Attempts 12 GUIDE TO SYMBOLS ...

Page 3: ...d the serial number of the lock to reset it if the combination is lost or forgotten and the door is open it is important that you keep a record of the lock serial number in a secure place Because of the LOBC feature it is not an easy task to remove the back cover to read the lock serial number after the lock is installed If you do not have the serial number from the removable label follow the proc...

Page 4: ...ditions that exist on the lock If you continue to dial left and if the number of consecutive unsuccessful attempts is three or more the unsuccessful attempts count will be displayed along with a lightning bolt You must slow down or stop dialing to pause and view the count The count will disappear when you dial left to resume operations or when the lock powers down DIALING A COMBINATION The X 09 re...

Page 5: ...for this target number until you reach the correct number Redial Entire Combination If A The screen goes blank before the lock bolt is retracted B A lightning bolt is displayed Caution An X 09 lock will initiate a timed lockout of 3 minutes when ten consecutive wrong combinations have been dialed Each additional unsuccessful attempt to open the lock will initiate another timed lockout If the numbe...

Page 6: ...ctory combination 50 Stop on 50 and pause briefly 5 Dial right CW After OP with a right arrow OPen right is displayed continue dialing to the right to retract the lock bolt Note If at any time the dial remains stationary for more than 40 seconds the lock will power down LCD will go blank requiring the operator to redial the entire combination TO CLOSE THE LOCK 1 Turn Dial to the left CCW a minimum...

Page 7: ...ordinate Combination will no longer open the lock SET OPERATING MODE AND CHANGE COMBINATIONS Use the Change Key Figure 2 provided with your X 09 to set the desired operating mode and combinations If at any time during the process you see the Key and Lightning Bolt symbols displayed stop the sequence and return to Step 4 If at any time after you start the change key process you see only a Lightning...

Page 8: ...nter the Supervisor s combination first Note If you have lost or forgotten the current combination s and are using the serial number method to complete this process enter the six digit serial number at this time just as you would enter a six digit combination 6 Dial right CW until the symbol SL for Select Mode is displayed 7 Now dial left CCW to select the mode of operation 01 for Single Combinati...

Page 9: ... number 30 Stop Dial right to second number 60 Stop Dial left to third number 90 Stop 10 Dial right CW briskly The new combination will be displayed two times two digits at a time Once the combination has been displayed the symbol C2 Enter Combination 2 will appear Note If the correct combination is not displayed you may pull out the Change Key and the lock will allow you to reset the combination ...

Page 10: ... If the door of your container is shut and the X 09 is accidentally locked with the Change Key still inserted in the back of the lock you can recover with the following procedure 1 Allow the lock to power down After 40 seconds the display will go blank Wait an additional 2 minutes for full power down 2 Dial right CW until lock is powered and the number of successful openings is flashing Caution Do...

Page 11: ...OMBINATION MODE In this mode two combinations must be correctly and consecutively entered to open the lock Either combination may be entered first however the second combination must be started within 40 seconds after the first combination is completed First Operator 1 Dial left CCW until lock is powered 2 Dial the first combination in the correct manner to open the lock i e left CCW to dial the f...

Page 12: ...to dial the second number left CCW to dial the third number EXAMPLE Combination 25 50 75 Dial left to first number 25 Stop Dial right to second number 50 Stop Dial left to third number 75 Stop 3 Dial right CW UL UnLocked is displayed indicating that the Subordinate Operator can now open the lock using only the Subordinate Combination The X 09 will now operate as if it were in a single combination ...

Page 13: ...ial right CW LU Locked Up will be displayed indicating the lock cannot be opened The Subordinate Combination will not open the lock again until the Supervisory Combination is redialed to UnLock UL the lock once again CORRECT METHOD OF CLOSING RELOCKING CONTAINER 1 Close the container door 2 Turn Dial to the left CCW a minimum of one complete revolution to extend the bolt 3 Turn Dial to the right C...

Page 14: ...mes the lock has been opened since it was manufactured When the lock has been opened 9 999 times the next time that the lock is opened the count will begin again at 0 and continue to increment TO CHECK THE NUMBER OF UNSUCCESSFUL ATTEMPTS The X 09 keeps a record of the number of unsuccessful attempts to open the lock This count will only be displayed when there have been three or more consecutive u...

Page 15: ...r Count Incorrect Combination Dialed xx times The error count is only displayed when there have been 3 or more consecutive unsuccessful attempts UL Unlocked LU Lock Up Key Change Key Symbol The Change Key has been inserted and the lock is in Change Combination Mode SL Select Mode of Operation EC Enter Combination PO Pull Out Change Key CC Confirm Combination or Combination s C1 Enter first Combina...

Page 16: ...NOTES ...

Page 17: ...Notice The information in this manual is subject to change without notice and does not represent a commitment on the part of Kaba Mas Kaba Mas shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material 2002 2008 Kaba Mas All rights reserved ...

Reviews: