35
1.
For a PowerStar version of the lock, power the lock by briskly turning
the dial back and forth in both directions.
2.
Press
Enter
and then
2
. Simultaneous green and red flashes display.
3.
Enter the Master User combination. Simultaneous green and red
flashes display.
4.
Enter
08
. Simultaneous green and red flashes display.
5.
Enter
08
again for verification. Simultaneous green and red flashes
display.
6.
The lock will now open by entering any two-digit number (except “00”)
followed by
502550
.
Retrieve Audit Records
The lock’s audit feature will track the following types of lock transactions in
sequential order of occurrence:
•
lock opened
•
Users added/deleted
•
Supervisor enable/disable Subordinate User(s)
•
PIN activated/changed
•
wrong try lock out
•
in Dual access mode, first combination entered
•
lock date/time set (Model 400 only)
•
lock shelved
•
lock mode changed
•
audit report retrieved
•
time delay override
•
beginning of timed lockout
For a Model 400 or 500 lock, each transaction will include a date and time
stamp. The number of audit records stored by the lock varies according to
lock model. Refer to the “Lock Models” section on page 1 for detailed
information. If you have purchased the PC software for reporting capabili-
ties, the audit trail data stored in the lock can be read from the lock and
taken to the Auditcon PC for reporting.