DOOR THICKNESS: 

SCREW LENGTH:

 

1.25 1.00

 

1.375 - 1.75 

1.25 (PROVIDED)

 

1.875 - 2.00 

1.50

 

2.125 - 2.50 

2.00

 

2.625 - 3.00 

2.50

 

3.125 - 3.50 

3.00

 

3.625 - 4.00 

3.50

 

4.125 - 4.50 

4.00

DIAL RING INSTALLATION
1. Place the exterior (dial ring) mounting plate cover over the exterior (dial ring) 
  mounting plate and mount the dial ring using the two #8-32 x 5/16 machined 
  screws that are provided.
2. Refer to the section on installation of the dial ring in the “INSTALLATION 
  INSTRUCTIONS FOR THE X-10 TYPE 1F HIGH SECURITY ELECTRONIC LOCK” 
  booklet for additional dial ring installation instructions.
 
CUSTOM CUTTING TUBES AND SPINDLE 
1. Refer to the sections for cutting tubes and for cutting the spindle in the 
  “INSTALLATION INSTRUCTIONS FOR THE X-10 TYPE 1F HIGH SECURITY 
  ELECTRONIC LOCK” booklet for detailed instructions needed to cut the tubes and
  spindle to fit your specific installation.

INSTALLATION COMPLETION INSTRUCTIONS 
1. Continue to follow the instructions in the “INSTALLATION INSTRUCTIONS FOR 
  THE X-10 TYPE 1F HIGH SECURITY ELECTRONIC LOCK” booklet for the 
  remainder of the lock installation. Please note that when those instructions refer to
 the 

lock case assembly, the installer should consider that as meaning the 

  CDX-10 unit.

DO NOT REMOVE THE X-10 LOCK CASE FROM THE CD BASE.

Summary of Contents for CDX-10

Page 1: ...CDX 10 Please read all instructions carefully before putting your CDX 10 into operation INSTALLATION OPERATING INSTRUCTIONS...

Page 2: ......

Page 3: ...FROM OUTSIDE 4 TO OPEN FROM INSIDE 5 LIFE SAFETY OPERATION 5 CDX 10 INSTALLATION 6 BASIC TOOLS NEEDED 6 INSTALLATION KIT CONTENTS 7 CDX 10 PARTS FOR INSTALLATION 8 STRIKE INSTALLATION 9 TEMPLATE 9 DE...

Page 4: ...X 10 Type 1F Lock P N 539 0512 which is enclosed in this Operating Installation Instruction Kit Please refer also to the Model CDX 10 Lock System drawing P N 524 021 for lock nomenclature which is al...

Page 5: ...lso the dead bolt Extension Bolt NOTE The life safety switch can only be depressed while the lock bolt is withdrawn 2 Depress the life safety switch located by the LIFE SAFETY label on the dead bolt u...

Page 6: ...stallation BASIC TOOLS NEEDED 1 Medium Phillip s screwdriver 1 2 2 Standard hacksaw 32 teeth inch 3 Small flat file 4 Small vise or a Port A Vise Harbor Freight P4742 5 Drill bits No 25 11 32 1 2 6 El...

Page 7: ...sing 10 Lubricant Lubriplate 11 Dial Hub Locating Gauge 12 Hex Key 5 64 13 Spindle Screw The Zebra Connector and Zebra Connector Housing are assembled at the factory but may come apart during shipment...

Page 8: ...PARTS FOR INSTALLATION 1 CDX 10 Dead bolt lock assembly 2 CDX 10 Base hardplate 3 Dial hub assembly 4 Strike Kit 1 of 4 Types 1 2 3 or 9 Strike 9 is shown in photo with screws 5 Spindle 6 Dial ring as...

Page 9: ...e the template to the door 3 Center punch all hole positions onto the door 4 Drill the 1 2 diameter spindle hole through the door 5 Drill the two 2 CDX 10 attaching screw holes nearest the strike open...

Page 10: ...LECTRONIC LOCK booklet for additional dial ring installation instructions CUSTOM CUTTING TUBES AND SPINDLE 1 Refer to the sections for cutting tubes and for cutting the spindle in the INSTALLATION INS...

Page 11: ......

Page 12: ...not be liable for technical errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material 2012 2015 Kaba Mas X 10...

Reviews: