10
Change the Shelved Mode combination
You may change the default Factory Combination of 50-25-50 to a new
combination to be used while the lock is still in Shelved Mode. Once you
have changed the combination for the irst time, you may want to change the
combination again to a different Shelved Mode combination. You can even
change it back to the Factory combination of 50-25-50 if you would like.
CAUTION:
For security purposes, do not select a combination from personal data such as birth date,
phone number, etc. You also should not share the combination. It is a secret.
REQUIRED ITEMS:
CURRENT SHELVED MODE COMBINATION
NOTE:
You can only change the Shelved Mode combination while operating
in Shelved Mode. Once a lock is “activated” in any mode, the Shelved Mode
combination returns to the Factory Default of 50-25-50.
To change the Shelved Mode combination:
1. Press * Key
→
EC
Press * key until the letters EC (Enter Combination) appear in the display
window.
2. EC
→
Enter Shelved Mode Combination
→
OPn
Enter the current Shelved Mode combination (either 50-25-50 or a changed
Shelved Mode combination) by sequentially pressing those digits on the lock
keypad. The numbers will be displayed on the LCD as they are entered. When
the combination has been correctly entered, the bolt will begin moving to
open the lock and the lock will display “---” while the bolt is moving. The bolt will
stop moving when it reaches the open position and the lock will display OPn.
3. OPn
→
Retract Bolt
Rotate the container handle to to unlock the lock, and the lock display will be
cleared.
4. Open Container Door
5. Press * Key
→
CLb
Press * key until CLb is displayed.
6. CLb
→
Press #8
→
EcF
Press the “#” button followed by the “8” button. EcF (Enter current Factory
combination) will be displayed.
7. EcF
→
Enter Current Shelved Mode Combination
→
EnF
Enter the current shelved mode combination, “EnF” (Enter new Factory
combination) will be displayed.
8. EnF
→
Enter New Combination
→
CnF
Select and enter the new combination. “CnF” (Conirm new Factory
combination) will be displayed.
NOTE:
The new Shelved Mode combination should be recorded and stored in a
secure area.
9. CnF
→
Enter New Combination
Enter new combination again to conirm. EOP (End of Process) will be
displayed.