7
AFTER LOCK CASE INSTALLED
Warning: Do not insert batteries into input unit prior to having all
connections into lock secured. Also, ensure no power is applied to the
24V terminal prior to all connections being completed.
1. Attach Power Cable to lock while not connected to power supply. Insert the
red wire into +24 Volt terminal and tighten screw terminal with small lathead
screwdriver. Insert the black wire into GND terminal and tighten screw terminal
with small lathead screwdriver
Warning: The bolt works sensor must be used and attached for correct
operation of the motorized dead bolt. Incomplete connections or faulty
sensor operation could result in lock malfunctions. Ensure correct
operation by following Bolt works sensor command (#75 as described
later in document).
2. Attach bolt works sensor nominally open wire to indicated terminal (Figure 5).
Tighten screw with lathead screwdriver.
3. Attach bolt works sensor common to GND terminal. Tighten screw with
lathead screwdriver.
4. Attach 5-pin cable from the entry assembly into the 5-pin port on the lock
(Figure 5).
5. Attach 6-pin cable from the entry assembly into the 6-pin port on the lock
(Figure 5). (For Bluetooth operation only.)
6. Double check all cables are inserted into the correct slots on the lock.