Document Number 548.0418 Rev. AX — 02/2019
15
Figure 5 - Tube-Cable Assembly Relationships
8
Installation of the Dial Ring
1. Remove the two screws from the dial ring assembly cover and remove the cover.
NOTE:
Make sure the tubes are projecting through the door. If not, the tubes are
not seated properly in the lock or they were not cut to the proper length. Correct
the problem before proceeding.
2. If necessary, rotate the tube retainer in the dial ring so that the cables come
through the notch in the tube retainer.
3. Feed the cables through the tube retainer on the dial ring assembly and place the
dial ring assembly over the end of the tubes. Make sure the tubes are seated in the
tube retainer on the dial ring assembly.
4. Attach the dial ring to the door with the dial ring mounting screws and tighten to
the specified torque.