Document Number 548.0418 Rev. AX — 02/2019
21
Connect Cable Assembly
1. Refer to the figures below depending on the handing of the installation. Spread the clevis of the cable assembly
(116036)
over the appropriate lever arm
(515091)
, and insert the clevis pin
(515095)
through both the pivot arm and the cable
assembly
(116036)
, so that the groove on the pin is located in front of the plate assembly.
2. Press on the “E” – Retaining Ring
(515094)
over the clevis pin
(515095)
.
3. DO NOT tighten the brass nut on the threaded plug at this time.
(515094) Clip, "E" Retaining Ring
(116036) Cable Assembly
(515095) Pin, Clevis
(515091) Lever Arm
Clevis Pin Attachment
(515094) Clip, "E"
Retaining Clip
(515091) Lever Arm
(116036) Cable Assembly
(515095) Pin, Clevis
Clevis Pin Attachment Side View
Adjust Cable Length
The effective cable length may be changed by turning the brass threaded plug into and out of the turnbuckle. The
cable length must be adjusted so that as the lever of the Best 9K is turned, the
DKX
Series bolt is fully retracted and
latched back just before the Best 9K lever set latch bolt clears its strike.
Summary of Contents for DKX-10