Document Number 548.0418 Rev. AX — 02/2019
27
Request to Exit Installation
All
DKX
-10 and
DKX
-19 LRL locks include Request to Exit (RQE) functionality. If the installation does not support RQE the
switch may be removed from the lock system.
NOTE:
The switch is approved for a maximum load of 24 Volts AC or DC and 1 Amp.
1. With the mounting plate
(514052)
installed on the door, one of the 3/8” holes will line up with the previously drilled 3/8”
hole in the door.
RH and RHR Wire Routing
LH and LHR Wire Routing
2. Connect the RQE switch, using the markings on the bottom of the switch for terminal description, to the auxiliary system
and route any excess wires into the holes shown above to avoid pinching wires.
3. At this point the sliding plate assembly
(514053)
should be installed as described in Section 3.
4. The switch wires should be routed away from the latch bolt in such a way that they do not interfere with the return
spring in the plate assembly.
5. Bias the switch so that when the latch bolt is in the extended position the snap action arm on the switch rests in the
notch on the lever cam
(515079)
.
6. Attach the interior lever
(A89062)
to the cam
(515079)
and rotate it. Check to make sure that the switch is made as the
lever rotates, but that the switch is not biased so far down that it causes a bind in the system.
7. Remove the lever
(A89062)
and continue installation as described in Section 3.