(P/N) 760.128 Rev G 12/13 • © copyright 2004-2013
Kaba Mas LLC
Page 1 of 2
MANAGER INSTRUCTIONS
BASIC SERIES
3802 Firmware Dual-Handed Swing Bolt Lock or Dead Bolt
SUPER MASTER RESET (SMR)*
• 8 Digit code – default code 5-5-5-5-5-5-5-5 [consistent with other LA GARD locks]
• If the default code is not changed before Manager changes his or her code then the SMR option will be lost, unless hard reset of the lock
is performed.
• Once set the SMR cannot be changed, unless hard reset.
FACTORY RESET PROCEDURE
Remove Battery.
• Hold down key “0” for 10 seconds to discharge all internal capacitors.
• Connect Reset Box (p/n 6066) to alarm box connector. Put the battery back in place, factory reset is completed.
Disconnect Reset Box.
• Lock configuration is: only manager code exists, set to 1-2-3-4-5-6. Audit file not cleared.
• Lock is operational with manager code only; other users are deleted.
LOCK USERS
Manager
• Open Lock
• Change Combination
• Enable/Disable User
• Delete User
Users
• Open Lock
• Change Combination
STANDARD LOCK FEATURES
Wrong Try Penalty
• Entry of four (4) consecutive invalid combinations initiates a five (5) minute delay penalty. Lock responses during the penalty period are
as follows:
- The LED will flash every ten (10) seconds. If any key is pressed, there is no response.
• Once the penalty period has ended, two (2) consecutive invalid combinations will initiate another five (5) minute penalty period.
Low Battery Warning
• Repeated audio/visual signals (LED flashes/beeps) during Lock opening indicate the battery is low and should be replaced immediately.
• If the battery level becomes too low to safely operate the Lock, pressing any key will initiate the low battery warning. The battery must be
replaced before the Lock will operate.
LOCK OPERATING CONVENTIONS
• If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation.
• To access lock commands, enter combination and hold down the last digit until Lock double signals and the LED stays on.
LOCK RESPONSES
Standard Operations
• Manager Menu – LED on during operation
• Double signal - two (2) LED flashes and two (2) beeps indicate entry is valid or accepted.
• Triple signal - three (3) LED flashes and three (3) beeps indicate invalid or not accepted.
• Lock must be opened within 4 seconds once a valid combination has been entered.
• To open a container with a Swing Bolt Lock, turn the container handle to the open position and open the door.
• To open a container with a Dead Bolt Lock, turn the keypad or dial to retract the bolt and open the door.
• When closing a container, verify that it has been secured.
Dual-handed
Swing Bolt Lock
Dead Bolt Lock
3000 Entry
(Swing Bolt Only)
3750 Entry
KEYPADS:
LOCKS:
3715 Entry
(Swing Bolt Only)
3190 Privat
II
(Optional)
3710 Entry
(Swing Bolt Only)
3035 Entry