SMARTLINC

Multiple Lock System

user operating instructions

CHANGING YOUR CODE
ALWAYS PERFORM THIS OPERATION WITH 
THE DOOR OPEN

If you have access to multiple locks, you must 
repeat this procedure on each lock you have 
access to.

1. Press any key to power up SMARTLINC.

  •  Display will show either “ENTER COMBO”
    or “SELECT LOCK” when two or more locks
    are installed.
2. Select lock if two or more locks are installed.
3. Enter “zero” six times
4. Enter existing six (6) digit code one time (and
  insert eKey

II

, if set-up).

5. Enter NEW six (6) digit code two times (and
  insert eKey

II

,if set-up, after 2nd entry).

  •  If a valid code is entered the LCD will display
    “USER UPDATED”
6. If a mistake is made wait thirty (30) seconds
  and repeat steps 1- 4.
  •  Old Code will remain valid if a mistake is made.
  •  In case of a mistake, LCD will display “ERROR!”
7.  Test lock operation several times before closing the door.

CHANGING YOUR BATTERY

1. Remove black plastic battery compartment cover (located
  at the bottom of the keypad) by gently pulling downward on
  its handle.
2. Allow the battery and its attached leads to drop down and
  out of the battery compartment. If it does not drop, gently
  pull on the battery until it does.
3. Remove the connector by unsnapping it from the two
  terminals on the top of the battery.

Never Pull on the Battery Leads

4. Connect a new 9-Volt Alkaline battery to the battery clip.
5. Push the battery and the leads completely up into the
  battery compartment.
6. Install the battery cover by placing one
  side of the cover in position and then
  pressing the other side into position with
  your finger.

WARNING: The port for the eKEY

II

 is a data 

port only. Connecting power to this port will 
damage the system.

NOTE:

 This system comes equipped with an 

Auxiliary Power Box (APB). If primary power is 
lost, the APB will maintain power to the audit 
clock for 90 hours. 

THE UNIT WILL NOT 

FUNCTION UNTIL PRIMARY HAS BEEN 
RE-ESTABLISHED, i.e. batteries have been 
replaced or A/C power has been connected.

AVAILABLE FEATURES
USER CODE

•  Open Lock
•  Change Code
•  Set Immediate Time Lock, if enabled
•  Time Delay Extension, if enabled
•  Temporary Time Lock, if enabled

MULTIPLE LOCKS

•  Up to Five

TIME DELAY

•  Programmable on each lock
    -  Delay Period: 1 - 99 minutes
    -  Open Period: 1 - 19 minutes
•  Two Time Delays Can Run At Once

DUAL CODE

•  Two Codes required to open

eKEY

II

 MODE

•  Programmable on each lock; requires code and key for entry
•  Available to Manager and Users only, if enabled

WRONG TRY PENALTY

•  Four (4) consecutive invalid codes initiates five minute delay period

LOW BATTERY WARNING

•  Repeated audio and visual signal (LCD readout and repeated
  beeping) during opening indicates battery low

A

UDIO AND VISUAL SIGNAL

•  Double signal (LCD readout and unit beeps) indicates entry is valid
  or accepted
•  Triple signal indicates invalid or not accepted

TIME LOCK

If enabled, see Manager Instructions for operation.

© copyright 2006  

(P/N)12-245 v3 • 9/08 

Kaba Mas LLC

page 1 of 2

Optional eKey

II

P/N 40169

SELECT LOCK

XX

ENTER COMBO

X-X-X-X-X-X

OLD CODE
X-X-X-X-X-X

NEW CODE

X-X-X-X-X-X

CONFIRM NEW

X-X-X-X-X-X

USER 

UPDATED

ERROR!

Please note: If using the SMARTLINC with the eKEY

II

 feature, remove the key after each insertion to begin the next step. If the eKEY

II

 is 

left in the key port, the SMARTLINC will not respond to any key stroke.