9
INSTALLATION OF GENERATOR CABLE
AND CABLE GUIDES
1. Place the generator cable into the dial ring housing recess containing a post
used for positioning the cable. (See diagrams in Appendix B.) The hole in the
cable must be positioned over the post on the dial ring, and the fi ve gold tabs
must be exposed.
2. The Zebra connector and Zebra connector housing are assembled at the
factory but may come apart during shipment. If so, insert the Zebra connector
back into the Zebra connector housing before proceeding.
CAUTION: The Zebra connector is an
electrical connector. Keep it clean!
3. Place the generator Zebra connector
and connector housing assembly over
the generator cable, and press it into the
recess. The hole in the Zebra connector
housing must be positioned over the post
in the dial ring. Be sure that the black Zebra
connector housing is positioned as shown
in Figure 15.
4. Install at least one of the stick-on cable
guides in an appropriate position to restrain the cables. (See Figure 16 for
possible locations.)
5. Route the cables through the cable guide that was just installed.
Figure 14 - LCD and ZIF connectors
Figure 15 - Zebra Assembly
ZEBRA CONNECTOR HOUSING