PREPARATION FOR NEW INSTALLATION OF THE LOCK
1. Use the template to establish the exact relative locations of all of the necessary
mounting holes for the lock case and the dial ring, when necessary.
2. The lock case mounting screws require drilled and tapped 1/4-20 screw holes.
3. The dial ring mounting screws require drilled and tapped #8-32 screw holes.
4. The spindle hole must be 3/8 inch diameter, minimum.
Note:
If the spindle hole is less than 3/8 inch, refer to Appendix C of the
manual for instruction on small spindle hole installation.
Figure 4- Tube-Cable Assembly Relationships