10
6� Remove spindle screw and spindle from lock case prior to cutting� Carefully cut
the spindle so that it will be flush to the dial hub after installation.
Caution:
The spindle should not extend past the dial hub once installed but may
be recessed up to 1/32 inch below the surface of the hub. If it extends past the
dial hub, it must be filed to flush. (See Figure 18.)
7� Remove all burrs from the spindle�
InsTallaTIon of The dIal
hub and dIal
1� Slide the spindle into the lock case�
Note that the square portion of the
spindle must be aligned with the
square hole in the lock case� Insert
spindle screw and tighten� (For torque
specifications, see Page 1.)
2� Apply lubricant to the hub bearing
surface� (See Figure 19�)
3� Make a bend in the dial hub locating
gauge at its midpoint� This will keep it
from acting as a spring as the hub is
positioned for locking to the spindle�
4� Place the Dial Hub Locating Gauge
over the spindle and between the dial
hub and the bushing in the dial ring
cover� This sets up an initial 0�010
inch end play� (See Figure 20�)
5. Tighten the inner setscrew first. Now
SECURELY tighten the setscrews in
the dial hub to 17-20 inch-pounds of
torque (a minimum of 1 inch deflection
of the handle of the hex key)�
6� Remove the dial hub locating gauge�
Spindle flush to
hub or recessed
up to 1/32
"
figure 18 - spindle flush
or recessed
figure 17 - mark spindle flush to hub
Figure 19 - Apply Lubricant to Hub
Figure 20 - Place Gauge Between
Dial Hub & Bushing
Summary of Contents for X-10
Page 1: ...INSTALLATION INSTRUCTIONS X 10TM Type 1F HIGH SECURITY ELECTRONIC LOCK...
Page 18: ...16 Notes...
Page 19: ...17 Notes...