Version 02/15/2016
Page 24 of 40
Mounting instructions 82132/3xxx CB 30
9
Notes
These mounting instructions are the basis for different lock certifications. The installation of the locking system must
be carried exclusively in accordance with these instructions; otherwise, you may lose any warranty claims and/or the
product certification.
In addition, the current guidelines of the certification institutes must be taken into account and complied with.
Use only high-quality alkali/manganese batteries. Low-quality batteries may trigger oxidations, which can result in functional
failures of the locking system.
The cabinet must not contain any residual humidity or aggressive gas vapors (e.g., from painting), to prevent the contact
surfaces from being attacked.
During installation make sure that no dirt or cleaning agents (e.g., filler residues or cold cleaners) enter the locking system.
The locking system and the key must never be greased or make contact with other lubricants or aggressive liquids, it must
be cleaned with a moist cloth only (no aggressive cleaning agents).
The locking system is designed for use in the temperature range from +10° C to +50° C and at a humidity of 30% to 80%
(non-condensing).
The actuating torque on the key / the spindle must not exceed 2.5 Nm.
Modifications to the locking system or key can result in malfunctions and must therefore be refrained from. Never open the
lock housing. Dismount the fitting only for battery replacement and perform it strictly according to the specifications of these
operating instructions. In doing so, avoid touching or damaging electronic components. Otherwise you will endanger the
locking system and possibly lose any warranty claims.
To use the inputs and outputs on the lock side (labeled "in/out" at the lock), the locking system must be de-energized during
wiring, i.e., the batteries in the input unit and power supply units must be removed! Otherwise, the lock electronics may
become damaged.
The locking system is suitable for installation in secure storage units made of steel, provided with or devoid of padding
materials. Installation in units made of other materials such as plastic is not allowed.
The proper installation of the locking system must be done by trained personnel, as must be the in-factory functional test
prior to delivery of the secure storage unit. In doing so the perfect functioning of the locking system and of any further
systems that may be connected to it or controlled by it (e.g., boltworks) must be ensured.
It is recommended, that unauthorized persons have no access to security sensitive parts of the lock, also the door of the
safe, where the lock is installed, is open.
10 Technical data
10.1
Power supply
Normally power supply takes place by means of 2 batteries of type AAA /LR 03 (1.5 V) in the input unit.
Optionally, power supply can take place via the following components:
a)
via an intruder detection system and the alarm box (item no. 3001001550
)
b)
when using an alarm box (see above) connected to signaling equipment without power supply option by means of an
additional 12V power supply unit (item no. 3002501230)
c)
via a 9V power supply unit (item no. 3002501220) directly to the "power" connection socket of the lock.
Notice: It is strongly recommended to use the original Kaba Mauer power supply unit (article numbers see above),
otherwise the correct function of the lock system cannot be ensured.
10.2
Lock
Bolt stroke: 12 mm
Bolt projecting end in locked condition: approx. 14 mm
Bolt width: 25,4 mm; Bolt height: 15 mm
The maximum allowed forces acting on the bolt (opposite to the direction of closing, maximum locking force and lateral load)
can be seen from EN 1300. It is recommended providing in the design a bolt lock on both sides or a bolt support.