Version 02/15/2016
Page 37 of 40
Mounting instructions 82132/3xxx CB 30
13.3.4
Fastening the base part
The Combi B 30 base part (11) is now screwed onto the storage unit door using the three enclosed screws (9), as shown in
Figure 31, (for the drill hole specification, see chapter 12.2). Ensure tidy cable routing:
Depending on the position of the cable passage hole, it may be necessary to pass the connecting cable (12) below the base
part (11) to the cable passage hole. In doing so, do not squeeze or damage the cable (see note in chapter 13.3.3), but make
sure that it is laid below the base part up to the passage hole in the cabinet.
Notice:
The turnament to fix the base part (11) must not exceed
1,3 Nm
!
Notice:
To fasten the base part, only the enclosed screws (9), whose screw head size match exactly the input unit,
should be used! Should you use any other screws, you have to make sure that the screw head height does not exceed
2.6 mm, since otherwise the rotary handle (7) cannot be mounted or dismounted!
13.3.5
Inserting the batteries
Insert two batteries (no. 14) of type AAA / LR 03 and ensure correct polarity; otherwise, the lock (1) will not function and damage
may occur. It is highly recommended using high-quality brand batteries and replace them as a precaution every 24 months
at the latest.