background image

 
 
 
 
 

 

 

 

 

Date Feb. 10, 2016 

page 2 of 3 

Mounting instructions  70040 VAROS 

 

 

Install the Kaba Mauer escutcheon follow the footprint given in sketch 2.

 

 

 

 

 sketch 2: escutcheon footprint, all dimensions in mm (inches) 

 
 

 

Installation of the Kaba Mauer guiding tube: 

  

The key hole in the door of the secure storage  unit has to be dimensioned between 11 and 13 mm (following DIN 2768-
mH),  considering  the  outer diameter  of  the  tube  shown  in  sketch  3, 

the secured area  given  in  sketch  4  and  the security 

requirements of the secure storage unit. According to  sketch 4, all areas outside the given zone have to be protected by 
the armoring of the secure storage unit. 

 

During the installation and adjustment make sure that the key guiding tube gets properly put onto the two round projections 
on  the  lock  case  as  well  as  to  the  round  groove  of  the  key  hole  cover.  Please  take  care  that  after  installation  the  key 
guiding tube is in a 90° angle to the lock and the escutcheon (see sketch 5: section of mounting situation).  
Length (L) of the key guiding tube in mm:  

L =   X  + 

2,4 

[+0/-0,5]   mm  

Length (L) of the key guiding tube in inches:  

L =  X   +   0,095  [+0/-0,019]  inches   

(see sketch 5).

 

 

sketch 3: key guiding tube, all dimensions in mm (inches) 

 

  

 

 

 

sketch 4: security zone of the lock

sketch 5: section of mounting situation, 

 

             all dimensions in mm (inches) 

       all dimensions in mm (inches) 

 

 

 

After the installation make sure that the key can be easily inserted into the lock and turned with minimal force and without 
binding. 

 