Installation
Operating Manual
16
k1evo821 - 201606
Kaba mechatronic cylinder surface
Round profile
2.
Remove the retaining plate by pulling it forwards.
4.1.7
Fitting the cylinder in the mortise lock
≥ 7.5
1
2
3
≥16
1
Door
2
External fitting or external rosette
3
Antenna
ü
Fitted mortise lock
ü
Fitted adapter plate, depending on the installation situation
ü
Internal fitting unscrewed from the door, depending on the installation situation
1. Align the cylinder cam parallel to the cylinder pin.
2. Slide the cylinder with the surface-mounted e-module onto the mortise lock
from the inside of the door.
3. Align the cylinder antenna in the mortise lock.
Note:
The antenna (3) must be at least 7.5 mm from the external fitting (2). The
cylinder must protrude by at least 16 mm on the inner side.
4. Screw in the forend screw.