5.3
Installation
5.3.1
Preparation
If necessary, drill holes for the frame bracket.
A dimension drawing of the frame can be found above.
Surface cable mounting:
Use the spacer frame (only indoors).
Break open the cable inlet on the spacer frame.
Lead the cable away at the bottom or at the side in a siphon shape.
NOTICE
Only connect the wires when the power is switched off.
Procedure
1. Pull the cable through the rear panel or the spacer frame.
Screw the rear panel or the spacer frame to an even surface.
The rear panel or spacer frame must not lose its shape.
Small bumps can be balanced out using the sealing pad.
Lead the cable away in a siphon shape to prevent the ingress of water.
2. Connect the cable strands to the connection terminal.
An overview showing the assignment of connection terminals can be found in Chapter 5.4.2
NOTICE
The pin strip can be damaged. Observe the following instructions.
3. Slide the registration unit in a parallel position over the rear panel or the
spacer frame.
4. Press the registration unit against the rear panel or the spacer frame until it clicks into position at
both the top and the bottom.