Kaba Registration Unit RFID 90 02
28
TM_ RegistrationUnits_201406_en.docx
Procedure
1. Pull the cable through the rear panel or the spacer frame.
Screw the rear panel or the spacer frame to an even surface.
The rear panel or spacer frame must not lose its shape.
Small bumps can be balanced out using the sealing pad.
Lead the cable away in a siphon shape to prevent the ingress of water.
2. Connect the cable strands to the connection terminal.
An overview showing the assignment of connection terminals can be found in Chapter 6.4.2
NOTICE
The pin strip can be damaged. Observe the following instructions
3. Slide the PIN keypad in a parallel position over the rear panel or the spacer
frame.
4. Press the PIN keypad against the rear panel or the spacer frame until it clicks into position at both
the top and the bottom.
6.4
Connection
6.4.1
Connection with quickwire
TM
Technology
With the innovative quickwire technology, the wiring is performed completely separately from the
electronics on the mounting plate (rear panel or spacer frame). The electronics are mounted as a unit
during commissioning. The practical click connection makes mounting simpler and means the
registration unit is quickly changed in case of repair.
In addition, it is possible to upgrade from a registration unit without a PIN to a registration unit with PIN
with no or minimal changes to wiring.
6.4.2
Connecting the Coaxial Cable
Terminal Number
Meaning
Control Unit
6
Antenna cable shield wire
AS
7
Antenna cable inner conductor
A+