Kaba Registration Unit PCB 90 00
TM_ RegistrationUnits_201406_en.docx
33
7.3
Typical Maximum Reading Distance
1 = Badge, ISO 14443A
2 = Key fob, ISO 14443A
3 = Badge, LEGIC RF
4 = Badge, ISO 15693
5 = Kaba elolegic smart key, LEGIC RF
7.3.1
Reading and Writing Distance with Direct Mounting on Metal
If the registration unit is mounted in metal facades or a metal frame, the reading and writing distance
will be approx. 10% smaller than in an RFID neutral environment (wood, masonry).
7.4
Technical Data
Dimensions
70 x 70 x ~13 mm (length x width x height)
Temperature Range
- 25° - +70°C (operation)
- 40° - +85°C (storage)
Ambient Conditions
Relative humidity
0% - 95%, non condensing
Application
On-site assortment of switches or sockets
Coaxial cable
Recommended: RG 174/U, 50 Ohm
Supplier: Huber + Suhner
max. lenght 30 m
7.4.1
Accessories
Supplier
Type
Amacher
Basico
Domino
Busch-Jäger
Feller
EDIZIOdue, pluggable
NUP
Gira
E2
Event
Surface
S-Color
Standard
Jung
CD500
CD Play
ST 550
Legrand
Diplomat
Merten
7.5
Conformity
See Chapter 12.