7.7
Local enrollment
It is possible to enroll fingerprints directly on terminals of devices with biometric
reader (optional).
7.7.1
Call up and requirements
Software option
The "Local Enrollment" function is a software option. The function can only be
entered if the required entry is available in the license file.
A function call up without corresponding license generates an O5 error record.
Disable and enable by the host
The "Local Enrollment" function can be enabled or disabled with the data records I2
and I3. The "Local Enrollment" function is enabled by default.
Function call up
The "Local Enrollment" function must be called up by a booking. The used function
key must be set to limit value check "30".
Enroll PIN
To protect access to the biometric database in addition a Password is requested. The
password can be set by using the parameter setting “Password parameter setting
and customer number” (X02 record).
A password is not stored by default.
Timeout
If the user does not enter anything within 70 seconds, the "Local Enrollment"
function is automatically closed.
Please see manual of the B-Client PDC6 terminal software for a detailed description
of the parameter and data records named above.
7.7.2
Biometric management functions
After call-up, the system menu is displayed. The current assignment of the internal
CBM database is additionally displayed. The example shows that the database
contains 23 of 500 possible finger templates.
Please Select Function (C=Cancel)
DB usage 23 of 500 entries used
Enroll
Unenroll
List
Identify
Erase
The functions of the system menu are activated by means of the function keys below.