User Manual B-Net 93 60
Set-up
01/2006
© Kaba Benzing GmbH
43
6.2
Set-up of optional hardware
NOTICE!
Before the modification of devices already in operation, save parameters and
master records.
After modification, the changed parameters must be sent from the communication
software to the device.
Remark regarding the use of serial interfaces (Serial Line)
Each serial interface can only be assigned to one function (Reader, Host Line or
Sub Line). It must be considered that the respective interface is deactivated in the
other service functions.
6.2.1
Second reader (external reader, e.g. CCD hand scanner)
Hardware requirements:
•
The terminal must be equipped with option BEX301 (interface RS232).
•
The second reader must be connected to the RJ-45 connector on the
BEX101 mother board, refer to chapter 5.6.8
Settings in the service module:
•
Hardware Settings/Serial Line Communication Parameter,
refer to chapter 7.3.7.2
• COM1:
Enabled
•
Bits per second: 9600
• Data
bits:
8
• Parity
NONE
• Stop
bits:
1
•
Hardware Settings/Reader, refer to chapter 7.3.7.3
• Reader
2:
Enabled
• Interface:
COM1
• Type:
Barcode
•
Hardware Settings/Sub Line Parameter,
refer to chapter 7.3.7.5
•
Sub line:
Disabled
6.2.2
Replacing a reader module with other reader type
Settings in the service module:
•
Hardware Settings/Reader, refer to chapter 7.3.7.3
• Reader
1:
Enabled
• Interface:
COM2
•
Type:
(new reader type)