Version 2014-02-28
Page 32 of 48
Operating instructions 82132/3xxx CB 30
20 Overview of authorizations
The authorizations of individual operators are as follows:
Operator ID
Code
designation
Authorization
-
Inspection key
-
Opening without OD/OST and without guard time
-
Assigning of a new master code
-
Resetting the lock
-
Changing the lock configurations using software without
knowing the master code or changing it.
00
Master code
-
Opening, if necessary, with silent alarm
-
Changing of the own code
-
Activating, blocking, releasing, deleting user and courier, with
activated double code as well
-
Activating / deactivating double code
-
Programming / deleting OD/OST
-
Neutralising the take-off contact
-
Reading out audit
-
Activating, deactivating silent alarm
-
Access via PC software
01..30
User codes
-
Opening, if necessary, with silent alarm
-
Changing of the own code
95
Courier code
-
Opening without OD/OST, if necessary, with silent alarm
-
Changing of the own code
-
Assembler code
-
Opening
-
Valid only until the real start-up of the lock,
NOT A REAL CODE, not suitable for permanent use
Table 30: Authorizations
21 Overview of the programming commands
Action
Command Authorization
Changing own code
P
each
Reading out audit
P1
Master
Acti deactivating OD/OST
P2
Activating user
P3
Bl releasing user
P4
Deleting user
P5
Code status query
P6
Acti deactivating double code
P7
Acti deactivating silent alarm
P8
Acknowledging the take-off contact message
P9
Resetting the lock
P0
Key
Reassignment of the master code
P