background image

The lock is now configured as follows:

Users 1, 2, and 9 are active.

Users 3, 4, 5, 6, 7, and 8 are blocked and 

can not be enrolled later.

Time delay Override is Enabled. (User 9)

Silent Alarm is Enabled.

Summary of Contents for COMBOGARDPRO

Page 1: ...Introducing the ...

Page 2: ... FEATURES 10 Codes Manager and 9 User Time Delay 99 min delay 19 open Code length 6 to 9 PC programmable Software Fully Key Pad configurable Audit 63 first in first out non erasable ...

Page 3: ...Lock Setup Via The Key Pad Tutorial ...

Page 4: ...Lock Setup Steps Exit Pre set mode Select Code Length Install Users Select Additional Features Finalizing Configuration ...

Page 5: ... Exit Pre set mode Step 1 Press and Hold 0 key until unit signals twice Step 2 Enter the default Manger Code 5 5 5 5 5 5 Lock will open and is now in the Setup and Test mode ...

Page 6: ...5 5 5 5 5 Hold down the last digit until the lock signals twice and the LED stays on PRESS 8 key PRESS 9 the desired code length then PRESS 0 Re enter PRESS 9 then PRESS 0 to confirm The code length has now been change to 9 digits To verify Enter 5 5 5 5 5 5 5 5 5 the lock will open ...

Page 7: ...the last digit until the lock signals twice and the LED stays on PRESS 8 key PRESS 6 the desired code length then PRESS 0 Re enter PRESS 6 then PRESS 0 to confirm The code length has now been change to 9 digits To verify Enter 5 5 5 5 5 5 the lock will open The lock is now set to operate using 6 digits codes ...

Page 8: ... 5 5 5 5 5 Hold down the last digit until the lock signals twice and the LED stays on PRESS 1 key Select User ID 1 Enter user code 1 1 1 1 1 1 re enter code 1 1 1 1 1 1 User is installed Enter 1 1 1 1 1 1 to verify Lock will open ...

Page 9: ... 5 5 5 5 5 Hold down the last digit until the lock signals twice and the LED stays on PRESS 1 key Select User ID 2 Enter user code 2 2 2 2 2 2 re enter code 2 2 2 2 2 2 User is installed Enter 2 2 2 2 2 2 to verify Lock will open ...

Page 10: ...ast digit until the lock signals twice and the LED stays on PRESS 1 key Select User ID 9 User 9 will later be enabled to override time delay Enter user code 9 9 9 9 9 9 re enter code 9 9 9 9 9 9 User is installed Enter 9 9 9 9 9 9 to verify Lock will open ...

Page 11: ...Lock Programmable Feature Chart 7 6 5 4 3 2 1 0 SILENT ALARM DUAL CODE TIME DELAY OVERRIDE MODE ...

Page 12: ... 5 5 5 5 5 Hold down the last digit until the lock signals twice and the LED stays on PRESS 8 key Enter 0 this will maintain the current code length Enter Option 5 Time Delay Override and Silent Alarm Re enter 0 then 5 to confirm ...

Page 13: ...er available Un enrolled Users are blocked and can not be added later Also the lock s operational mode can no longer be changed To change Manger code Enter 5 5 5 5 5 5 Hold down the last digit until the lock signals twice and the LED stays on PRESS 0 key Enter New Manager code Example 1 2 3 4 5 6 Re enter 1 2 3 4 5 6 to confirm ...

Page 14: ...The lock is now configured as follows Users 1 2 and 9 are active Users 3 4 5 6 7 and 8 are blocked and can not be enrolled later Time delay Override is Enabled User 9 Silent Alarm is Enabled ...

Page 15: ...me values Delay 1 minute Open 1 minute Time Delay Setup Enter Master code 1 2 3 4 5 6 Hold down the last digit until the lock signals twice and the LED stays on PRESS 9 key Enter the desired delay period 0 1 Enter open period 0 1 Re enter 0 1 0 1 to confirm ...

Page 16: ...igured as follows Users 1 2 and 9 are active Users 3 4 5 6 7 and 8 are blocked and can not be enrolled later Time delay Override is Enabled User 9 Silent Alarm is Enabled One minute Time Delay with a one minute Open Period ...

Page 17: ...ter either the Manager or a User code To override the delay Enter User 9 s code Note If Time Delay is active it can only be deactivated or delay value decreased in the Open Period Selecting 0000 deactivates the Time Delay Feature ...

Page 18: ...This concludes the lock setup with via the key pad Thank You ...

Reviews: