6
E-730/630/750/79E/ RT Series Installation Guide - PK3677_T_04_16
4.1 Insert the slotted end of the spindle (D) into the outside
housing until it locks, at the correct position for the exit
device (see Fig.4). The spindle can be removed by pull-
ing on it, and re-inserted if oriented incorrectly. Choose
a spindle that engages by 1/8” minimum in the exit
device chassis and that it is not too long to bottom-
out against the exit device mechanism to jam the lock
assembly, once it is tightened down.
4.2 Place the outside housing (B) on the door. (with gasket
(C) if required)
4.3 Attach Adaptor Plate (E) to the lock (B) using 3 Flat
Head screw (F)(12-24nc).
4.4 Attach the Exit Device chassis (G) to the Adaptor Plate
(E) using 2 screws or 4 screws (H) depending on the
Exit Device. For Detex only, use 2 or 4 Flat washers (Q).
4.5 Make sure the lock and the Exit Device are well aligned
and then tighten screws.
4.6 Follow the manufacturer’s instructions to complete
the installation of the exit device and the appropriate
strike.
**Dorma 9300/9400 Series are Panic hardware only (not fire rated)
**Dorma F9300/F9400 Series are Fire rated hardware
Spindle Position
Arrow S3888
Detex 10/F10
Detex 20/F20
Detex V40
**Dorma 9100/9300/9400
**Dorma F9100/F9300/F9400
Hager 4500
Precision 21/FL21
Precision 22/FL22
Sargent 8710
Von Duprin 98/99
Von Duprin 9847/9947
Von Duprin 9827/9927
Yale 7100-36
Yale 7160
Yale 7170
Arrow S1908/S3908
Arrow S1708/S3708
Arrow S1808/S3808
Von Duprin 9875/9975
H
Q
D
C
B
G
Q
H
E
F
Fig. 3
Fig. 4
4
Install Lock & Exit Device on the door
D INSTALL THE LOCK AND THE EXIT DEVICE