8
E-730/630/750/79E/ RT Series Installation Guide - PK3677_T_04_16
Activate the panic bar. The latch bolt or rod
retracts fully.
Turn the outside lever downward. The latch bolt
or rod does not retract.
If the latch bolt or rod retracts, verify that
the batteries are properly installed.
If the lever feels tight (hard to turn, or does
not return easily to its horizontal rest position),
check the spindle length vs. the door thickness
(the spindle may be too long). Check that the
slotted end of the spindle is inserted in the lock
housing hub, not the exit device.
Test the lock’s response to keycards: a Test key-
card, a Grand Master keycard, and an Emergency
keycard.
Insert keycards as shown below, with the mag-
netic stripe facing toward the door and to the
left. For 79E, present cards to reader.
A Test the Lock Before Programming
Normal Entry: Use the Test keycard with the
reader. The
red
and
green
LEDs each flash once
and then the
green
LED flashes for four sec-
onds.
Turn the outside lever downward while the
green
LED is flashing. The latch or rod retracts
fully. Release the lever, then turn it again. The
latch or rod must not retract after the LED
stops flashing without first inserting the
keycard .
B Lock Programming
Program the lock with its Common Area number
(exit devices are usually programmed as common
areas, see Reference Manual).
Use the Grand Master keycard with the reader.
The
green
LED flashes. Turn the outside lever
downward while the
green
LED is flashing. The
latch or rod retracts fully and the LED stops
flashing after 4 seconds. Release the lever,
then turn it again. The latch or rod must not
retract again without first inserting the
keycard .
C Emergency Keycard Access
Use the Emergency keycard with the reader.
The
green
LED flashes for 4 seconds. Then, turn
the outside lever downward. The latch or rod
retracts fully .
While standing outside the room, close the door
and ensure that it is properly latched. Open the
door using the Grand Master keycard using the
same procedure.
Caution! Perform the following procedures
in order, with the door OPEN unless other-
wise indicated.
!
FDU
Program the lock using the FDU and the
E-760/770/790 communication cable (see
Reference Manual). If this is not a new installation
but a replacement of a single lock or a group of
locks in a property already equipped with the Kaba
Locking system, transfer the security informa-
tion from a neighbouring lock to the new lock by
using the Reset Addresses function (see Reference
Manual resetting lock addresses).
ATLAS
Program the lock using the M-Unit (Maintenance
Unit). Refer to ATLAS User Guide.
I
n the case of a replacement lock resetting the
addresses will ensure that all past lost and stolen
keycards remain cancelled in the new lock and will
set the addresses for the Section, Floor, Group,
Zone and Area sub-master level so that staff key-
cards in use at the property will have the same
pattern of access to the door as before. This step
makes the lock replacement transparent so that
the new lock accepts and rejects the same key-
cards as the old lock.
Multihousing
Program the lock using the M-unit or EAMU FDU..
Refer to RezShield User Guide or FDU user Guide.
1
Panic Bar
2
Outside Lever
3
Electronics and Card Reader
E
TEST THE OPERATION OF THE E-730/750/79E LOCK
(For 630 lock go to Section H) (For RT lock series, please refer to system 6000 manual)
F
PROGRAM THE E-730/750/79E LOCK
(For 630 lock go to Section H) (For RT lock series, please refer to system 6000 manual)