O. ACTIVATE MANAGER ACCESS CODE
A Manager Code should be activated if it has been de-activated for a certain
time period - during a Manager’s vacation, for example, or if you created a
Manager’s Code, but never assigned it to anyone.
Required User Level: Master
O-1
Put the lock into Pushbutton Programming Mode.
O-2
Enter Command
301#
to activate a Manager Access Code.
O-3
Enter the ID location
NNN#
, where
NNN
is the specific User ID location,
024
for example.
O-4
Example of Complete Entry:
301#024#
.
O-5
Enter another
#
to indicate the end of programming.
O-6
The Manager Access Code will now work in that door with all the access
privileges assigned to a Manager User.
P. ACTIVATE SERVICE USER ACCESS CODE
A Service User Access Code should be activated if it has been de-activated for
a certain time period - during a Service User’s vacation, for example, or if you
created an Access Code but never assigned it to a Service User.
Required User Level: Master, Manager
P-1
Put the lock into Pushbutton Programming Mode.
P-2
Enter Command
302#
for Service User Functional Code.
P-3
Enter the ID location
NNN#
, where
NNN
is the specific User ID location,
025
for example.
P-4
Example of Complete Entry:
302#025#
.
P-5
Enter another
#
to indicate the end of programming.
P-6
You have now activated a Service User Access Code.
Q. ACTIVATE ALL USER ACCESS CODES
You may need to activate all users if you have de-activated the whole group -
after a lockout, for example. This procedure will re-activate all regular and
Service User Access Codes that are not active.
Required User Level: Master, Manager
Q-1
Put the lock into Pushbutton Programming Mode.
Q-2
Enter Command
398#
.
Q-3
Example of Complete Entry:
398#
.
Q-4
Enter another
#
to indicate the end of programming.
Q-5
You have now activated all regular User and Service User Access Codes.