12
USER LEVELS
Five different classifications of users can perform various operations at the lock.
Master User
- The Master User is the top-level manager who performs the
initial lock setup activities and can program all lock functions. There is a
maximum of one Master User per lock.
Manager
- A Manager can program all lock functions except:
• defining the Access User Code length
• modifying the lock ID
• modifying master user Access Code
• changing date and time
• resetting to default value
• activating lockout mode
• adding / deleting / enabling / disabling a Manager User. The number of
Managers is limited only by available user table space (299 maximum
because one (000) is reserved for the Master Code).
Access User
- An Access User has the ability to open the lock. The number of
Access Users is limited only by available user table space (299 maximum
because one (000) is reserved for the Master Code).
Service User
- A user with an Access Code valid for a configurable period of time.
This period of time starts on the first use of the code. Each Service User combina-
tion is automatically deleted from the locks memory after its period of time
expires. The number of service users is limited only by available user table
space (299 maximum because one (000) is reserved for the Master Code).
M-Unit User
- The M-Unit User (Maintenance User) is only applicable when
used with a handheld PDA and the E-Plex software, sold separately. Please refer
to the “E-Plex Standard” Software User Guide for M-Unit operation.
Note:
The total number of codes enrolled into the lock at any given time
cannot exceed 300 (plus M-Unit User if applicable), regardless of code
classification.
USER CODES
Each time you add a user to give access to a door, you must program the door
with an Access Code for them. This User Access Code can also be referred to
as a PIN (Personal Identification Number). If you modify the Access Code for
an existing user, the procedure is the same.
User Codes must not have the exact same numbers in the same position
as the Master Code.
The Master Code
00004992
is used as an example in the table below.
Summary of Contents for E-PLEX 30XX SERIES
Page 1: ...OPERATIONS MANUAL E PLEX 50XX 30XX SERIES ...
Page 19: ...Notes Notes 19 ...
Page 20: ...20 Notes ...
Page 21: ...21 Notes ...