Lock Function Options for E-Plex 2xxx/5xxx Series
The E-Plex 2xxx/5xxx mortise and thumbturn locks can be configured on-site
to work in various lock functions, which are relevant to those defined by BHMA
(Builders Hardware Manufacturers Association). The options available in a given
lock are determined by the respective lock’s mechanical locking configuration as
noted below. All E-Plex 2xxx/5xxx products are shipped in factory default mode,
and are configured as an Entry lock function (04). This section will help you
change your lock from an Entry lock into another function as listed for
each mechanical locking configuration, if required.
E-Plex 2xxx/5xxx Cylindrical (without thumbturn) and Exit Trim
Configuration
1) Entry Lock Function with Passage Enabled (04)
2) Storeroom Lock Function (07); Note: Not applicable to E-Plex 5200 & 5700
E-Plex 2xxx/5xxx Cylindrical (with thumbturn)
1) Entry Lock Function with Passage Enabled (04)
2) Privacy Lock Function (15)
E-Plex 2xxx/5xxx Mortise with Deadbolt
1) Entry Lock Function with Passage Enabled (04)
2) Residence Lock Function (08)
3) Privacy Lock Function (15)
E-Plex 2xxx/5xxx Mortise without Deadbolt
1) Entry Lock Function with Passage Enabled (04)
2) Storeroom Lock Function (07); Note: Not applicable to E-Plex 52xx & 57xx
Definition of Kaba Terms:
Personal Identification Number (PIN)
- A password; a chain of numbers you
choose and use to gain access to a lock
Credential
- Evidence of authority, status, rights, entitlement of privileges, or
the like
Passage
– When a lock is in passage mode, the door is unlocked and requires
no access credential to gain entrance.
Entry Lock
- A lock with an Entry lock function is normally locked. Entrance is
only granted via an authorized access credential (i.e. PIN code). However, the
lock can be put into and taken out of passage mode by an authorized operator
(i.e. Master User). During passage mode, the lock is unlocked and no access cre-
dential is required.
Storeroom Lock
- A lock in the storeroom function can never be put into pas-
sage mode as this feature is purposely disabled. Other than that, it works the
same as an Entry lock. Note: For E-Plex 52xx & 57xx locks, this lock function
can be emulated via the software.