Residence Lock
– A lock with the residence function stays in unlocked mode by
default. It can be locked either from inside by throwing the deadbolt or from
the outside by pressing the “#” key three times (###), followed by a valid user
PIN (Personal Identification Number) which is the code [Credential - PIN for
E-Plex 2xxx/50xx and E-Plex 52xx; PIN, Card or PIN, Card or PIN & Card for
E-Plex 5700 or in the case of E-Plex 5700, the PIN, Card or PIN followed by
card, depending on the required access credential]. When the same or the next
valid user enters the credential to open, the lock will open. It will stay in
unlocked mode until you lock it back either from inside by throwing (projecting)
the deadbolt or from outside by entering first # # # followed by a valid creden-
tial. If the deadbolt is thrown, and then you egress (leave the room) by turning
the inside lever, the deadbolt will retract. The lock will open and will stay open.
One application for locks of this type of functionality is in university dorms.
Every time you flip the privacy thumbturn from the vertical (unlocked) to hori-
zontal (privacy locked) position, the Red LED will flash once and when you flip
it the other way (horizontal to vertical), the Green LED will flash once, in either
case indicating the privacy status.
Privacy Lock
– The privacy function enables a lock to have access restricted to
only privileged users. The mortise lock with deadbolt privacy or the cylindrical
lock with a privacy thumbturn from the factory must be setup in the field to be
a Privacy lock. Normally, only the Master and Managers’ credential will over-
ride the privacy and unlock the door. However, if you use the E-Plex 2xxx/5xxx
STD software, other “privileged” users can also be programmed to override the
privacy to unlock the lock. For E-Plex 5200 & 5700, the Enterprise software is
needed to enroll “privileged” users that can override the privacy function.
Procedure to setup a Lock Function as Entry lock (04), Storeroom lock (07),
Residence lock (08) or Privacy lock (15):
• All lock types (cylindrical, mortise, exit device operators etc) coming out of
the factory will be in Entry lock function (04) mode, by default. Performing a
hard reset as explained in the Operations Manual will always reset the lock to
an Entry lock function.
• For any lock function other than the Entry lock, you must change the lock
function and setup the desired lock function -> 07 (for E-Plex 2xxx/5xxx only),
08 or 15. This can be done only at the lock pushbuttons (and not through the
software) while the lock is still in factory mode with the Master code as
12345678.
Important: Anytime a lock has been reset via a hard reset, this set-up pro-
cedure will have to be performed unless the lock is to remain as
an entry lock.