13/37
13
Where:
XXXXXXXX is the 8 digit construction pin, entered twice
(0-9)
Set date
001#
MMDDYY#MMDDYY#
Where:
MM is the month (01-12)
DD is the day (01-31)
YY is the year (07-99)
Note that the date is expressed in local time.
Set time
002#
HHMM#HHMM#
Where:
HH is the hour (00-23)
MM is the minute (00-59)
Note that the time is expressed in local time and in 24-hour time
format.
Set temporary passage
mode duration
005# HH#
Where:
HH is the number of hours the lock should be in passage mode
(00-24). A value of 00 will abort the passage mode.
Configure lock using an
admin card
100#
(None), just present the card.
No # is required after presenting the card.
Activate/deactivate
passage mode
399# A#
Where:
A is 1:activate or 0:deactivate
Activate/deactivate
lockout
499# A#
Where:
A is 1:activate or 0:deactivate
Perform diagnostics
500#
None.
When this command is entered, the following operations are
done:
The green led turns on for 2 seconds with a high pitched
sound and then,
The red led turns on for 2 seconds with alow pitched
sound
Then the user must press keypad keys in this exact
sequence: 1 2 3 4 5 6 7 8 9 0
*
#
For each successfully pressed key, the green led turns on with a
high pitched sound. But if a wrong key is pressed or a pressed
key is not detected, the red led will turn on with a low pitched
sound indicating a problem with the lock electronics..
Identify lock model
501#
None.
When this command is entered, the lock identity green and red
led indicators are enabled (blink 9 times to indicate E5
9
00