background image

10

11

I-3

Insert the supplied tailpiece (e) vertically into the

outside lever/knob (b) as shown. Make certain that

you rotate the tailpiece so it will align with the inter-

changeable core. For screw cap type cylinders

(Schlage) (g), the tailpiece must be assembled

to the cylinder first with the tailpiece vertically as

shown. Insert the core into the outside lever/knob.

Note:

To remove the outside lever/knob from

the outside unit assembly, follow steps below.

I-4

Remove the interchangeable core (g).

Then remove the tailpiece (e).

Note:

You may want to use needle nose

pliers for some tailpieces.

I-5

Insert the release tool (d) into the

small hole (f) under lever/knob as

shown. Gently push lever catch up

until it clicks. Remove tool (d), then

remove outside lever/knob (a).

Note:

To remove the outside lever/knob from

the outside unit assembly, follow step below.

H-4

Insert one of the (supplied) keys (a) into

the outside lever/knob (b) and rotate it

counterclockwise 45 degrees. Insert

release tool (d) into the small hole (e)

under lever/knob as shown. Gently

push lever catch up until it clicks.

Remove tool (d), then remove outside

lever/knob (b).

I.

INSTALLING / REMOVING OUTSIDE
LEVER/KNOB

(Interchangeable / Removable Core Models)

Note:

Installing lever/knob to the unit assemblies

before mounting the unit assemblies may ease

initial installation.

I-1

Make certain the lever catch is up as shown in the

image (c). The lever catch should be flush around

the entire diameter of the outside driver. Make certain

the lever sleeve (f) is rotated to properly mate with

the outside lever.

I-2

Insert the outside lever/knob (a) unit it is flush

to the outside unit assembly (b) (levers fit closer

than knobs). To secure the outside lever/knob,

insert the release tool (d) (or screwdriver) into

the outside lever/knob as shown, and slide the

lever catch down until it clicks. Make certain

lever/knob is locked on.

g

vertical

b

b

e

e

b

b

a

a

d

d

a

a

f

f

d

d

a

e

e

b

b

45º

d

d

IC Lever Sleeve

RH

LH

f

e

g

c

Correct

Position

Incorrect

Position

Summary of Contents for E-Plex 5x00 Cylindrical

Page 1: ...5 x 0 0 C y l i n d r i c a l Installation Instructions...

Page 2: ...18 mm Screws Latch 1 25 mm Screws Security Screw Tool Set Screw Release Tool ASA Strike Battery Cover Screws The E Plex 5031 is a non handed lock that is preassembled for left hand installations It i...

Page 3: ...orter 13 8 35 mm connecting screws also supplied C 2 Reference Figure B For thicker door applications of 21 8 54 mm to 21 2 57 mm remove the two connecting screws a from the cylinder drive unit b Add...

Page 4: ...pressing latch bolt b in slightly until the outside unit assembly c rests flush against the door Ensure the red collar is seated in the top left mounting hole Note If the red collar appears to be too...

Page 5: ...tuted with a foreign part If the lock is used with a wall bumper the war ranty is null and void If a doorstop is required we recommend the use of a floor secured stop The environment and conditions of...

Page 6: ...oor Exercise Room This lock is New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock othe...

Page 7: ...nobs Secure the outside lever knob by rotating the key clockwise 45 degrees to the horizontal position Remove key 8 9 LH KIL Lever Sleeve RH f b b a a 45 G CHANGING KEY IN LEVER KNOB CYLINDER On key i...

Page 8: ...outside lever knob b and rotate it counterclockwise 45 degrees Insert release tool d into the small hole e under lever knob as shown Gently push lever catch up until it clicks Remove tool d then remov...

Page 9: ...push button on lock and then release the key 3 Red and green lights should begin flashing 4 Input 1 2 3 4 5 6 7 8 at lock within 10 seconds 5 You should hear sound of lock resetting and a high pitch...

Page 10: ...he door frame using two 1 25 mm combination screws c supplied c a b Correct Incorrect a b Caution Check the operation of the latch by making sure that the deadlatch a stops against the strike b as sho...

Page 11: ...Kaba Access Control 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kabaaccess com www e plexlock com PKG2992 1206...