28
Summary of LearnLok
TM
Pushbutton Programming Commands
Name
Command
Description of Command
Authorization
Configure
000 #
MMMMMMMM#
MMMMMMMM#
‘Modify Master User Access Credential (lock’s activation)’
(Always 8 digits)
Master
001 #
MMDDYY#
MMDDYY#
‘Date setup’ (MM = 01 to 12; DD = 01 to 31; YY = 00 to 99)
Master
002 #
HHMM#
HHMM#
‘Time setup’ (HH = 00 to 23; MM = 00 to 59)
Master
004 #
TT#
‘Unlock time setup’ (TT = 02 to 20 seconds)
Master, Mgr
005 #
TT#
‘Passage Mode Timeout setup’ (TT = 01 to 24 hours -
duration time in hours; 00 = no time limit)
Master, Mgr
006 #
TT#
‘Tamper time setup’ (TT = 00 to 90 seconds)
Master, Mgr
007 #
TT#
‘Tamper wrong try setup’ (TT = 03 to 09)
Master, Mgr
008 #
VV#
‘Buzzer volume control’ (VV = 00 to 03;
00 = off; 01 = Low; 02 = Normal; 03 = High)
Master, Mgr
009 #
LL#
‘Modify access length’ (LL = 04 to 08 digits)
Master
099 #
‘Reset to factory default values’, except access PIN length.
(Master, Managers, all other users and time/date are
retained if already programmed; Users are not reset.)
Master