31
Visual Feedback Message Definitions
Condition
Parameters
Green LED
Red LED
Duration
Rate
Valid pushbutton pressed
ON
OFF
1/10 sec
Once
Timeout expired
OFF
ON
1 sec
Once
Valid access credential entered/presented
ON
OFF
1 sec
Once
Access granted
ON
OFF
1/10 sec
Once
Access granted (battery low condition
ON
ON
1/10 sec
1 sec
Access denied
OFF
ON
1 sec
1 sec
Valid programming entry
ON
OFF
1 sec
Once
Invalid programming entry
(including duplicate access credential)
OFF
ON
1 sec
Once
Tamper shutdown beginning
OFF
ON
2 sec
Once
Tamper shutdown state
OFF
ON
1 sec
10 sec
Tamper shutdown ending
ON
OFF
2 sec
Once
*Communication starting
ON
OFF
1 sec
Once
*Communication ending
ON
OFF
1 sec
Once
*Communication aborted
OFF
ON
1 sec
Once
*Communication in progress
ON
(Alternate)
ON
(Alternate)
1/10 sec
1 sec
Deadbolt/Thumbturn Privacy Activated
OFF
ON
1 sec
Once
Deadbolt/Thumbturn Privacy de-activated ON
OFF
1 sec
Once
Hard Reset sequence progress
ON
(Alternate)
ON
(Alternate)
1/2 sec
Continuously
Hard Reset sequence ended successfully
ON
OFF
2 sec
Once
Hard Reset sequence failed
OFF
ON
2 sec
Once
*When used with the E-Plex Maintenance Unit (M-Unit) handheld and software only